![Broadcom 5720ZG Скачать руководство пользователя страница 113](http://html1.mh-extra.com/html/broadcom/5720zg/5720zg_user-manual_2815598113.webp)
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide
10.114 cputest
cmd:
cputest
Description:
TX / RX CPU Test. This test needs an input CPU file in the same location as
b57diag.exe. The default file name is cpu.bin or cpu05.bin unless specified by –f option.
Syntax:
cputest [iteration]
Options:
-f<string>
input filename
-n<DEC>
iteration (The default iteration is 1. 0 means run forever)
10.115 dmatest
cmd:
dmatest
Description:
DMA Test
Syntax:
dmatest [iteration]
Options:
-4
Allocate 4k-aligned buffers
-a<HEX>
NIC address (def=00002100)
-d
Display DMA info.
-f
Force to use 32-bit bus
-l<HEX>
Length of DATA to do DMA (def=00000400)
-n<DEC>
iteration
-o<HEX>
Buffer offset (def=00000000)
10.116 teste
Command:
teste
Description:
The command enables tests. It effects nictest, regtest, pkttest, and memtest
commands. The test must starts with test group alpha (a-d). If no number is
entered, all tests in that group are enabled.
Syntax:
teste [<tests> [<tests>…]]
page 104
Broadcom Confidential and Proprietary