OPERATION
The status alarms can be controlled by entering 97 followed by the status number 1
through 8 and
1 for enable
,
0 of disable
or
9 for poll
.
The analog (metering) alarms can be controlled by entering 98 followed by the analog
number 1 through 8, and
1 for enable
,
0 for disable
or
9 for poll
.
Power fail, silent sensor and temperature are controlled with 99 followed by
1 for power
fail
,
2 for silent sensor
and
3 for temperature
.
1 to enable
,
0 to disable
or
9 to poll
.
Some
examples
are listed below:
Enable Status 4 alarm:
9741
Disable Status 4 alarm:
9740
Poll Status 4 alarm enable:
9749
Enable Analog (metering) 5 alarm:
9851
Disable Analog (metering) 5 alarm:
9850
Poll Analog 5 alarm enable:
9959
Enable Power Fail Alarm:
9911
Disable Power Fail alarm:
9910
Poll Power Fail alarm enable:
9919
Enable Silent Sensor Alarm:
9921
Disable Silent Sensor Alarm:
9920
Poll Silent Sensor Alarm enable:
9929
Enable Temperature Sensor Alarm:
9931
Disable Temperature Sensor Alarm:
9930
Poll Temperature Sensor Alarm enable:
9939
NOTE:
To clear an alarm, press the star (
*
) key.