background image

e-mail: 

[email protected]   

voice: 

360.854.9559   

fax: 

866.783.1742

13

WVRC-8 Installation and Operation Manual

INSTALLATION

Dial-Up Programming

Follow the steps below to configure the WVRC-8 for dial-up operation.

Installing factory defaults.

Remove power from the unit.  Hold down the “PGM” button down while reinstalling the
power plug.  The “PGM” button must be held down for a few seconds after the power is
restored.   When the PGM button is released, the PGM LED will blink twice to show that
the defaults were loaded

.  

CAUTION!

If you reinstall factory defaults, the standard factory recorded voice prompts

are not reloaded.  The user MUST re-record the voice prompts.

NOTE:

The dial-up programming may be accomplished locally using the RS-232 serial

port or via the web using Telnet.  

WEBSITE:

Visit our web site for
product updates and
additional information.

Содержание WVRC-8

Страница 1: ...dcast Tools Inc Copyright 1989 2011 by Broadcast Tools Inc All rights reserved No part of this document may be reproduced or distributed without permission Visit www broadcasttools com for important p...

Страница 2: ...er Audio Output 12 TEMPerature Probe Input 12 Front Panel Mic 12 BT Link RJ45 Connectors 12 POTS Telephone Line RJ11 12 PGM RJ11 TT Phone 12 PGM RS232 DB9 Connector 12 Network Connector 12 Power Conne...

Страница 3: ...e 28 Java Applet 28 Main Screen 28 Login Dialog 29 User Setup Dialog 30 System Setup Dialog 31 Network Setup Dialog 32 Schedule Setup Dialog 33 Schedule Detail Dialog 33 Analog metering Setup Dialog 3...

Страница 4: ...rious injury or death can occur if a command channel is activated while you are performing maintenance on your equipment If you are performing maintenance on your equipment you should press the PGM bu...

Страница 5: ...eight are equipped with SPST relays for each raise on and lower off function The WVRC 8 is supplied with spoken words and phases in English while the user is free to record words and phases in their l...

Страница 6: ...els will damage your WVRC 8 and con nected equipment if it is not properly protected For lightning protection devices check out www polyphaser com and www itwlinx com UPS Standby Power System We recom...

Страница 7: ...record mode RING LED Illuminated when a telco call is being received ACCESS LED Illuminated when a valid access code is entered HOOK LED Illuminated when the unit is off hook TONE LED Illuminated when...

Страница 8: ...telco audio input TOP CLR Connector Balanced caller from telco audio output TOP GND Connector Audio ground SS LT SS RT Connector Unbalanced silence sensor audio input BOTTOM GND Connector Audio ground...

Страница 9: ...8R Connector Normally open dry relay contact Raise function TOP K5R K8R Connector Common wiper dry relay contact Raise function TOP K1NC K4NC Connector Normally closed dry relay contact Lower function...

Страница 10: ...an handle up to pos itive only 10 volts DC and must be ground referenced Connect your metering ground to the associated ground terminal Inputs are self calibrating and are based on an internal A D con...

Страница 11: ...transformer of any current of 50ma or more will work NOTE The primary 120vac of the wall transformer should be con nected to the utility company side of your service An UPS is suggested to power the...

Страница 12: ...able to the rear panel RJ11 jack labeled LINE and the other end to the telephone line NOTE Some cell phone services severely distort DTMF control tones resulting in unreliable control If you plan on u...

Страница 13: ...power plug The PGM button must be held down for a few seconds after the power is restored When the PGM button is released the PGM LED will blink twice to show that the defaults were loaded CAUTION If...

Страница 14: ...and under ASCII setup check the box echo typed characters locally NOTE Step by step COM port HyperTerminal setup instructions are available on line at www broadcasttools com under Downloads 3 Press t...

Страница 15: ...out alarms 1 8 are used for status inputs one through eight A H are used for analog metering inputs one through eight P for Power Fail S for Silence Sensor and T for Temp alarm The numbers after the a...

Страница 16: ...times the voice message will be repeated when the alarm is called out Since there is no way of knowing when the remote party answers the phone line the WVRC 8 will start playing the alarm message a f...

Страница 17: ...ss a valid Control Access code has been entered The Analog Debounce Timer is the number of ten second increments required for the analog metering inputs to accept an alarm condition For example if it...

Страница 18: ...ed NOTE The correct value on the analog metering input MUST be present for several seconds prior to entering program mode Once program mode is entered the analog metering inputs are locked and changes...

Страница 19: ...the menu Make changes or press ESCape to accept current values If changes are made all eight values must be entered in sequence When 2 is selected from the menu the following is displayed Make change...

Страница 20: ...nel RJ 11 jacks labeled PGM 2 Press the front panel PGM button this should illuminate the front panel PGM led 3 Enter the two digit address of the message you wish to program The list of messages are...

Страница 21: ...tus Input 7 17 5 Status Input 8 18 5 Analog Input 1 21 5 Analog Input 2 22 5 Analog Input 3 23 5 Analog Input 4 24 5 Analog Input 5 25 5 Analog Input 6 26 5 Analog Input 7 27 5 Analog input 8 28 5 Eng...

Страница 22: ...6 WEBSITE Visit our web site for product updates and additional information CONFIGURE DIP Switch settings NOTE The UP position is OFF DIP 1 Feature creep DIP 2 OFF Voice Temperature in Fahrenheit ON...

Страница 23: ...ased To query the new analog metering value press 1 again to repeat the value Audio I O functions are controlled with the following codes once the security code has been entered 01 Local MIC Monitor O...

Страница 24: ...d by 1 for power fail 2 for silent sensor and 3 for temperature 1 to enable 0 to disable or 9 to poll Some examples are listed below Enable Status 4 alarm 9741 Disable Status 4 alarm 9740 Poll Status...

Страница 25: ...VOIDS ALL WARRANTIES FROM BROADCAST TOOLS INC Ethernet setup NOTE If you are not familiar with Ethernet enabled equipment it may be useful to contact your IT department network administrator or networ...

Страница 26: ...1 1 If you do not already have NET Framework version 1 1 or greater dotnetfx exe installed you can download it from the Microsoft web site 1 Install the Device Installer software on the PC used for th...

Страница 27: ...2 168 1 101 5 If you are behind a firewall or router you will need to port forward not only port 80 but also open ports 3001 3002 10001 and set the SUN Java to direct NOTE To set up port forwarding re...

Страница 28: ...alerts are sent to registered recipients on the following conditions if enabled Analog Telemetry value exceeds high or low threshold Status state changes Silence sensor detection Power failure Tempera...

Страница 29: ...els giving virtual units of measure Login Button Displays the Login dialog described below Logout Logs the user out User Setup Displays the User Setup dialog described below System Setup Displays the...

Страница 30: ...virtual inputs User Monitor analog metering status and virtual inputs and activate relays Super Monitor analog metering status and virtual inputs activate relays and perform setup functions excluding...

Страница 31: ...age Station Call Letters Changes the station call letters displayed on the main page External URL Label Changes the label displayed on the user defined button External URL Defines the URL that is acti...

Страница 32: ...from the WVRC 8 Host ID Optional in the form host domain Recipient Addresses E mail addresses four of alert recipients Backup DNS Server IP address of DNS server NTP Server Address Time server address...

Страница 33: ...ime or repeating events The Schedule Setup Dialog displays a list of scheduled events and allows the user to edit the schedule event s details described under Schedule Detail Dialog below Edit Opens t...

Страница 34: ...a relay or alarm muting unmuting and a time when the action occurs The scheduler supports both day of month and day of week schedules Wildcards can be specified in any of the date time fields to creat...

Страница 35: ...event should occur or ALL if the event should occur every minute Second Select the second when the event should occur or ALL if the event should occur every second OK Saves the event and exits Cancel...

Страница 36: ...ent A D value with the user supplied value Low Alert A low alert is issued when the analog value falls below this value High Alert A high alert is issued when the analog value exceeds this value Alert...

Страница 37: ...anges the label associated with any of the status items ON Alert Enables alerts when this status item changes from OFF to ON ON Email Recipients Specifies which e mail recipients receive the ON alert...

Страница 38: ...tion Analog 2 Selects the second of two analog metering channels used in the calculation Constant Specifies the constant used in the calculation OK Saves the settings and exits Cancel Exits without sa...

Страница 39: ...olated RFI protection Internal jumper for Wet floating external 5 to 24 VDC or internal 5 VDC source Dry Open collector contact closures to ground or external source Power Failure input Optically isol...

Страница 40: ...022 1998 IEC CSPIR22 1993 Radiated RF emissions 30MHz 1000MHz Conducted RF Emissions Telecom Lines 150KHz 30MHz FCC Part 15 Subpart B Class B IEC 1000 3 2 A14 2000 IEC 1000 3 3 1994 Electromagnetic Im...

Страница 41: ...THER WARRANTIES OR REMEDIES TO THE MAXIMUM EXTENT PERMITTED BYAPPLICABLE LAW BROADCAST TOOLSAND ITS SUPPLIERS DISCLAIMALL OTHER WARRANTIES EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIE...

Страница 42: ...sttools com Copyright 1989 2011 by Broadcast Tools Inc All Rights Reserved Broadcast Tools Connection suggestion when using listed equipment with DSL Telco Phone Lines Modification Date 07 12 11 DSL M...

Отзывы: