![briwatec TOPAS E350 V Скачать руководство пользователя страница 29](http://html.mh-extra.com/html/briwatec/topas-e350-v/topas-e350-v_translation-of-the-original-instructions_2814612029.webp)
Maintenance
B125 06/16 Rev.1
TOPAS E350V-E600V
29
Fig. 18 Oil level monitoring
INFORMATION!
During assembly, ensure the sealing of the thread.
9.11
Maintenance intervals
Daily maintenance:
Checking of the oil level; see Fig. 8 page 22.
Monthly maintenance:
Check the pipelines and screw fitting for leaks and solid attachment, and
reseal/retighten if necessary.
Check the terminal boxes and cable insertion opening for leaks and reseal if
necessary.
Clean the ventilation slits of the machine and the cooling fins of the motor.
Clean the air grid of the oil cooler.
Annual maintenance:
Check the coupling for wear; see Chap. 9.6 page 25.
Maintenance according to the level of contamination
:
Clean the filter suction air; see Chap. 9.1 page 21.
Maintenance after 1,500 – 4,000 operating hours:
Oil change; see Chap. 9.2 page 21.
Air de-oiling element; see Chap. 9.4 page 23.
Oil filter
Gas ballast