![briwatec TOPAS E350 V Скачать руководство пользователя страница 19](http://html.mh-extra.com/html/briwatec/topas-e350-v/topas-e350-v_translation-of-the-original-instructions_2814612019.webp)
Commissioning
B125 06/16 Rev.1
TOPAS E350V-E600V
19
4.
Connect the motor and motor protection circuit breaker (for safety, a circuit
breaker, and for strain relief of the connecting cable, a cable gland must be
provided).
We recommend the use of circuit breakers with delayed switch-off according to
over-current conditions. Momentary overcurrent can occur during cold start of the
blower.
7.3
Commissioning
1. Briefly start the motor to check the direction of rotation (item 9, direction of
rotation arrow, Fig. 4 page 14).
2. After possibly correcting the direction of rotation, restart the motor and stop it
again after approx. 2 minutes to refill missing oil according to the oil level in the
sight glass on the filling point.
INFORMATION!
The filling point must not be opened when the pump is running.
3. Connect the suction line.