12 Fault Finding
Diagram 12.1
9247
CONTROL PANEL
RETAINING
STRAP
RETAINING
SLOT
12.1 Important Notes
Before trying to operate the boiler make sure that :
• All gas supply cocks are open and that the gas supply has
been purged of air.
• There is a permanent mains supply to the boiler.
• There is a heating demand from the external controls.
Always check for gas soundness after any service work.
12.2 Electrical Testing
Should there be any doubt about the voltage supply to any of the
components, it is possible to carry out a simple electrical test.
Important. On completion of the Service/Fault Finding tasks
which have required the breaking and remaking of the electrical
connections the earth continuity, polarity, short circuit and
resistance to earth checks must be repeated using a suitable
multimeter.
To carry out the electrical test, gain access, as follows:
Hinge down the control box and remove Torx screws and
unhook the rear panel, refer diagram 12.1.
Refer to the Wiring diagram 12.2 and fault finding charts
diagrams 12.3 and 12.4.