Regulators can be fitted if water economy is required.
* Yellow (5 litre) regulator may not be necessary on some gas water heaters.
** Important: It is a requirement of Instantaneous Electric Heaters that a stable flow
of water passes through the heater. This requirement can be satisfied by using a ‘flow
stabiliser’ fitted prior to the heater and should be adjusted to give a temperature of
between 45 – 50
°
C from the heater.
Flow regulators are factory fitted.
Study the table on the previous page and
decide which flow regulators etc. are
required for your particular situation.
Unscrew both inlet elbows from the valve
body and remove flow regulator/s as required
using long nose pliers and replace with insert.
Screw inlet elbows back onto the valve body.
Flow Regulators
Inlet
elbow
Compression
nut
Filter
Insert
Flow Regulator
Non return
valve
14