background image

BE6100 

Operating Instructions  

(Translation of original) 

 Brinkmann Pumpen 

Edition 08/2018 

Page 1 of 13 

  

 

BRINKMANN-Screw Pump  

BFS / TFS / FFS / BFS-H / TFS-H / BFG / FFG 

 
Brinkmann Pumpen 
K. H. Brinkmann GmbH & Co. KG 

Friedrichstraße 2    D-58791 Werdohl 

Tel.:  +49-2392 / 5006-0  

www.brinkmannpumps.de 

Fax.: +49-2392 / 5006-180  

[email protected] 

 
Subject to change without prior notice.

  

Order - No. : BE6100  ENGLISH

 

 

Содержание BFG Series

Страница 1: ...ge 1 of 13 BRINKMANN Screw Pump BFS TFS FFS BFS H TFS H BFG FFG Brinkmann Pumpen K H Brinkmann GmbH Co KG Friedrichstra e 2 D 58791 Werdohl Tel 49 2392 5006 0 www brinkmannpumps de Fax 49 2392 5006 18...

Страница 2: ...high backpressure The dis charge pressure needs to be at least 2 bar higher than the inlet pressure 2 2 Application range Screw pumps are designed for pumping filtered lubricating fluids Please consul...

Страница 3: ...tting oils coolants Max delivery pressure 60 bar BFG FFG with cast iron spindle housing 150 bar 200 bar for BFS FFS1 BFS FFS2 and TFS BFS FFS3 upon request 120 bar H Minimum dis charge pressure Ensure...

Страница 4: ...may be performed by the machine manufac turer or supplier on behalf of the plant operator Moreover the plant operator is to make sure that the contents of the operating manual are fully understood by...

Страница 5: ...shaft 1 counterclockwise Keep pump tilted until it is completely drained Pumps with mechanical seal G or axial thrust A 6 Place pump on a work bench 7 horizontally with the threaded port facing up The...

Страница 6: ...hoses should only be per formed by authorized specialists and must consider the applicable standards and local legislation Only use components which are rated for high pressure i e no brass Do not us...

Страница 7: ...lar case ATTENTION Defective pressure relief valves may lead to pump dam age Excess pressure can also damage other system compo nents or cause human injuries Do not direct the bypass flow from the pre...

Страница 8: ...thermal shock After connecting the electrical wires close the terminal box switch on the motor and check for the direction of rotation in the following manner ATTENTION The motor s direction of rotat...

Страница 9: ...t ensure that it has a safety reserve of 10 in terms of the nominal voltage of the mo tor In addition the size of the motor should pro vide a safety margin of 10 with respect to the max pump output Wh...

Страница 10: ...is cavitating because the temperature of the pumped liquid is too high Increase the supply or inlet pressure Lower the temperatur of the pumped liquid Consult with the manufacturer System pressure is...

Страница 11: ...from the nameplate 4 Spare part with item No e g Motor 1 11 Repair Instructions 11 1 Fitting the coupling Coat pump and motor shaft ends with a thin coat of Molykote e g Molybdenumdisulfphite and ins...

Страница 12: ...1 295 320 315 110 0 3 0 310 Dim A Distance between inner surface of the coupling hub and the motor shaft end Dim B Distance between inner surface of the coupling hub and pump shaft end Inner surface...

Страница 13: ...Conform ment l annexe I N 1 5 1 de la Directive Machines 2006 42 CE les objectifs de s curit relatifs au mat riel lectrique de la Directive Basse Tension 2014 35 UE ont t respect s Con respecto al po...

Отзывы: