Trouble shooter’s guide 

Fault

 

Cause

 

Remedy

 

Motor does not start, no motor 
noise 

At least two of the power supply 
leads have failed  
 
Overload has tripped 

Check fuses, terminals and supply 
leads. 
 
Inspect overload 

Motor does not start, humming 
noise 

One of the supply leads has failed 
 
Impeller faulty 
Motor bearing faulty 

See above 
 
Replace impeller 
Replace bearing 

Overload trips 

Pump locked up mechanically 
High on/of cycling frequency 

Inspect pump hydraulics 
Check application 

Power consumption is too high 

Wrong direction of rotation of im-
peller 
Lime or other deposits 
mechanical friction 

See above 
 
Clean pump mechanism  
repair pump 

Motor overheats 

High on/off cycling frequency 
Wrong power supply (voltage or 
cycles) 
 
Insufficient cooling 

See above 
Power supply must correspond 
with name plate rating 
 
Check air flow at motor fan 

Pump does not pump 

liquid level too low 
Pump mechanism faulty 
Pipe blocked 

Fill up liquid 
replace pump mechanism 
Clean pipe 

The pump pumps no chips 

Chip breaker worn or damage 

Replace the chip breaker 

Insufficient flow and pressure 

Wrong direction of rotation of im-
peller  
 
Pump mechanism silted up 
Worn pump mechanism 

Change over two power supply 
leads 
 
Clean pump mechanism  
Replace pump mechanism 

Incorrect flow or pressure 

Wrong power supply (voltage or 
cycles) 

Power supply must correspond 
with name plate rating 

Running noise/Vibration 

Foreign objects in pump end 
Impeller damaged 
Bearing/Bushing broken 

Remove foreign objects 
Replace impeller 
Replace bearing/bushing 

Содержание SBC1520

Страница 1: ...019 1 BRINKMANN Horizontal End Suction Pumps SBC1520 1820 Brinkmann Pumpen K H Brinkmann GmbH Co KG Friedrichstra e 2 D 58791 Werdohl Tel 49 2392 5006 0 www brinkmannpumps de Fax 49 2392 5006 180 sale...

Страница 2: ...AUTION indicates a hazardous situation which if not avoided could result in mi nor or moderate personal injury The signal word ATTENTION indicates a hazard ous situation which if not avoided may cause...

Страница 3: ...1 5 Chip geometry Chip bundles to max 100 mm Kinetic viscosity of the medium 45 mm2 s Temperature of me dium 0 80 C Dry running Dry running causes in creased wear and should be avoided During the test...

Страница 4: ...of the op erating manual are fully understood by the personnel 3 5 Safety instructions relevant for operation If hot or cold machine components involve hazards they must be guarded against acci denta...

Страница 5: ...iate hoist During any assembly or disassembly pro cess the pumps must be secured against tipping trough ropes for example at all times The pumps must be securely mounted to the tank CAUTION Risk of cu...

Страница 6: ...ectric shock All service work must be carried out by quali fied service personnel Pump must be discon nected from the power source and all rotating parts must stand still Reassure that pump is disconn...

Страница 7: ...e discon nected from the power source and all rotating parts must stand still Reassure that pump is disconnected from power source and cannot be switched on Verify that there is no voltage at the term...

Страница 8: ...ional load on the bearings The SBC pump should be operated in continual operation mode not pulsed mode The pump should transport medium with out chips for 1 2 minutes before being switched off 8 Servi...

Страница 9: ...m repair pump Motor overheats High on off cycling frequency Wrong power supply voltage or cycles Insufficient cooling See above Power supply must correspond with name plate rating Check air flow at mo...

Страница 10: ...20 27 Oil inspection window 27 Screw plug DIN 908 28 Sealing ring DIN 7603 29 O ring 30 Shaft seal 31 Socket head cap screw with lock DIN 912 32 Nut SBC1820 DIN 934 Item Description 50 Pump body 51 In...

Страница 11: ...e the key 79 from the insert shaft 91 and remove the spacer sleeve 57 Use two screwdrivers to push the impeller 75 from the insert shaft 91 Insert the screwdrivers between the impeller 75 and the pump...

Страница 12: ...d motor shaft WARNING Risk of jamming or crushing during pump installation or removal Secure pump with appropriate hoist ATTENTION Clean the contact surfaces of the insert shaft 2 inside and the motor...

Страница 13: ...g 27 Pump Installation Secure pump against fall ing over i e with use of safety straps Reconnect immersion pump as described in point 5 ATTENTION When putting the pump back into use make sure the dire...

Страница 14: ...2006 42 EG die Schutz ziele der Niederspannungsrichtlinie 2014 35 EU eingehalten With respect to potential electrical hazards as stated in appendix No 1 5 1 of the machine guide lines 2006 42 EC all...

Отзывы: