BRINKMANN-Cutter pumps SBC152
0…1820
BE8085
Edition
11/2019
2
Brinkmann
–Horizontal End Suction Pumps Series SBC1520…1820
Contents
1
Indication to the manual .................................... 2
2
Description of product........................................ 2
3
Safety instructions ............................................. 4
4
Transport and storage ....................................... 5
5
Installation and Connection ............................... 5
6
Start up / Shut down .......................................... 7
7
Operation ........................................................... 7
8
Servicing and Maintenance ............................... 8
9
Trouble shooter’s guide ..................................... 9
10
Spare part ........................................................ 10
11
Repair Instructions / Replacing the rotary
mechanical seal / the shaft clamp .................... 11
12
Disposal ........................................................... 13
13
EC declaration of conformity ............................ 14
1
Indication to the manual
This operating manual gives basic instructions
which are to be observed during installation, op-
eration and maintenance of the pump. It is there-
fore imperative that this manual be read by the
responsible personnel and operator prior to as-
sembly and commissioning. It is always to be
kept available at the installation site.
1.1
Identification of safety instruc-
tions in the operating manual
Safety instructions given in this manual non-com-
pliance with which would affect
safety
are identi-
fied by the following symbol:
Safety sign according with ISO
3864
– B.3.1
or where
electrical safety
is involved, with:
Safety sign according with ISO
3864
– B.3.6
The signal word
WARNING
indicates a hazard-
ous situation which, if not avoided, could result in
death or serious personal injury.
The signal word
CAUTION
i
ndicates a hazardous
situation which, if not avoided, could result in mi-
nor or moderate personal injury.
The signal word
ATTENTION
indicates a hazard-
ous situation which, if not avoided,
may cause a
risk to the machine and it’s function.
2
Description of product
2.1
General description of the pump
Pumps of the series SBC are one-stage rotary
pumps. The impellers are fixed on the driving
shaft extension. The pump shaft and motor shaft
are interconnected by means of a shaft clamp.
The cutting unit is cutting the chips and the semi-
open impeller with its large clearances allows to
pump the particles along with the coolant fluid
from the machine back to the filter. The SBC
pumps are capable of handling chip to coolant ra-
tios of up to 1.5% by weight.
Pump and motor form a compact and space-sav-
ing unit.
All pumps are equipped with double mechanical
seal.
These pumps are for horizontal installations next
to or underneath a tank. The pumps are foot
mounted and must be screwed down in order to
ensure a secure stance.
2.2
Intended use
These pumps are not self-priming and must be
gravity fed.
The pumps of the series SBC are suited for cut-
ting aluminum chips or similar materials and for
pumping these materials along with the coolant
fluid.
An agitator located at the pump suction helps to
break up and separate any large bundles of chips
o
r birds’ nests which reach the pump suction.
– Pay attention of the limit of application in
table 1!
The cutter pumps are intended for installation in
machines and cannot be operated alone.