background image

13

DISCLAIMERS

Brightline

 guarantees all its products to be free from defects in materials and

workmanship for a period of one (1) year from the date of shipment.

If any product is found to be unsatisfactory under this warranty, the buyer must notify

Brightline

 immediately.  Once a course of action has been determined, if it is neces-

sary to return the product to 

Brightline

 a Return Authorization (RA) will be issued.

Ship the product directly to 

Brightline

, 580 Mayer Street, Building #7, Bridgeville, PA

15017. The RA number should be marked on the shipping carton. The unit will be

replaced or put into proper operating condition, free of all charges. The correction of

any defects through repair or replacement by 

Brightline

 shall constitute fulfillment of

all obligations and liability of 

Brightline

 to the buyer under this warranty and the

contract of sale.

Brightline

 is not responsible for damage to its products caused by improper

installation, maintenance, or use; by improper electrical hookups; or by unauthorized

repairs.

Failure to notify 

Brightline

 of unsatisfactory operation or any improper or

unauthorized installation, maintenance, use, repairs, or adjustments shall terminate the

warranty and 

Brightline

 shall have no further responsibility under the warranty.

Brightline

 shall not be liable for special or consequential damages in any claim,

action, suit, or proceeding arising under this warranty or contract of sale, nor shall

Brightline

 be liable for claims for labor, loss of profits or goodwill, repairs, or other

expenses incidental to replacement.

Brightline

 makes no other warranty of any kind

whatsoever, expressed or implied, and all implied warranties of merchantability and

fitness for a particular purpose that exceed the obligation specifically described in this

warranty are hereby disclaimed by 

Brightline

 and excluded from this agreement.

All shipments, unless otherwise noted, are F.O.B. factory.

The customer is advised to inspect for shipping damage, apparent and/or hidden.

If detected, notify the transportation company and file your claim.

WARRANTY

PROCEDURES

580 Mayer Street, Building #7,  Bridgeville, PA  15017 

  phone  412.206.0106 

  fax  412.206.0146

www.brightlines.com

Содержание Stealth-T

Страница 1: ...peration and Installation Guide Evolutionary Lighting Systems 580 Mayer Street Building 7 Bridgeville PA 15017 phone 412 206 0106 fax 412 206 0146 www brightlines com 2011 Brightline L P All rights reserved Patent pending TM REV 11 17 2011 1 ...

Страница 2: ...ure that is energized or to work with your hands near an exposed socket that is energized A qualified technician should perform service on fixtures Do not remove the ballast cover until the unit has been de energized In case of lamp failure 1 Turn the fixture power off 2 Wait 30 seconds for the ballast to reset 3 Install the new lamp s 4 Turn the fixture back on Stealth T Fixtures Two lamp glare f...

Страница 3: ... BI option Louvers are also available for downward throw operation DN option Reflector Die cut code gauge cold rolled steel with 4 pull down spring latches Door frame may be removed from fixture without tools Luminaire Ballast High frequency electronic ballast with a power factor 97 THD 10 Class A sound rating Luminaire operates at 230VAC 50 Hz 51A Dimensions The overall dimension of the fixture b...

Страница 4: ...l the proper wiring must be run to each fixture Connect the control wires inside the fixture observing the proper color coding Install the control wiring above the ceiling See the Control Wiring section below 5 Fixtures can be mounted in two ways either flush mount in a hard ceiling such as plaster or drywall or mounted in a T Grid acoustical tile ceiling Installation Figure 3 Figure 1 Figure 2 Ha...

Страница 5: ...ucture in compliance with local codes Figures 4 and 5 Brightline recommends not relying on the t track alone to hold the weight of the fixtures 5 continued T Grid Ceilings Prepare the T Grid to receive the fixtures Fixtures are available for either 2 x 2 ft or 600 x 600 mm grid spacings Depending on the ceiling layout it may be necessary to add additional track sections and or prepare different si...

Страница 6: ...6 Non Dim Switched Riser Diagram L L L L L L L Line Voltage The fixture is wired to a source of AC power Line Neutral Ground only ...

Страница 7: ...nterior face and a power inlet for cord up to 15mm To wire the fixture 1 Untighten self tapping screw 2 Remove bracket from fixture enough to access terminal block 3 Feed leads through the grommetted hole 4 Wire according to label adjacent to terminal block Tighten contact screws 5 Re insert bracket into fixture and close with self tapping screw ...

Страница 8: ...Y CONDUCTORS DO NOT INSTALL INSULATION WITHIN 76MM 3 IN OF ANY PART OF THE LUMINAIRE DRY LOCATIONS ONLY IP RATING IP20 TURN OFF FIXTURE BEFORE RELAMPING CAUTION RISK OF FIRE USE WITH MAXIMUM 55 WATT LAMP BIAX 2G11 SOCKET AMBIENT TEMPERATURE Ta 25 C INPUT VOLTAGE GROUND EARTHLING INTERIOR FACE OF BRACKET ...

Страница 9: ...9 Page left blank intentionally ...

Страница 10: ...t of your order Two receptacles are provided to allow the control wiring to be daisy chained As each fixture is assigned an individual address fixtures on a DALI control line may be dimmed to differing intensities DALI control wiring is topology and polarity independant DALI control cables may be daisy chainned Keep the total wire run as short as possible See the literature that is provided with your...

Страница 11: ...low the control wiring to be daisy chained As each fixture is assigned an individual address fixtures on a DALI control line may be dimmed to differing intensities DALI control wiring is topology and polarity independent DALI control cables may be daisy chained Keep the total wire run as short as possible See the literature that is provided with your DALI controller or contact Brightline for details ...

Страница 12: ... to keep the lamps and lenses clean Use a dry non abrasive cloth to remove dust Avoid the use of materials that might scratch the lenses n o i t u l o S e s u a C e l b i s s o P m e l b o r P Fixture does not light 1 Missing or improper incoming power 2 Defective lamp s 1 Verify that the fixture is recieving proper voltage 2 Troubleshoot by replacing with known good lamps If necessary replace wit...

Страница 13: ...okups or by unauthorized repairs Failure to notify Brightline of unsatisfactory operation or any improper or unauthorized installation maintenance use repairs or adjustments shall terminate the warranty and Brightline shall have no further responsibility under the warranty Brightline shall not be liable for special or consequential damages in any claim action suit or proceeding arising under this ...

Страница 14: ...14 Notes ...

Отзывы: