7
en
•
Primer System:
This features a red primer to be used for starting in cool
temperatures. It does not have a manual choke.
•
Choke System:
This features a choke to be used for starting in cool temperatures.
Some models will have a separate choke lever while others will have a combination
choke/throttle lever. This type does not have a primer.
To start your engine, follow the instructions for your type of starting system.
Ready Start
®
System -
Figure
5
6
1. Check the oil level. See the
How To Check/Add Oil
section.
2. Make sure equipment drive controls, if equipped, are disengaged. See the equipment
manual for location and operation of these controls.
3. Push the stop switch (
A
), if equipped, to the on position (Figure 5).
4. Turn the fuel shut-off valve (
B
), if equipped, to the on position.
5. Move the throttle control (
C
) to the fast
position. Operate the engine in the fast
position.
6. If the product is equipped with an engine stop lever (
D
), hold the engine stop lever
against the handle (Figure 6).
7.
Rewind Start:
Firmly hold the starter cord handle (
E
). Pull the starter cord handle
slowly until resistance is felt, then pull rapidly (Figure 5).
Note:
If the engine does not start after three attempts, go to
BRIGGSandSTRATTON.COM
or call
1-800-233-3723
(in USA).
WARNING:
Rapid retraction of the starter cord (kickback) will pull your
hand and arm toward the engine faster than you can let go. Broken bones,
fractures, bruises or sprains could result. When starting engine, pull the starter cord
slowly until resistance is felt and then pull rapidly to avoid kickback.
8.
Electric Start:
Turn the electric start switch to the on/start position. See the
equipment manual for the location and operation of the switch.
Note:
If the engine does not start after three attempts, go to
BRIGGSandSTRATTON.COM
or call
1-800-233-3723
(in USA).
CAUTION:
To extend the life of the starter, use short starting cycles (five seconds
maximum). Wait one minute between starting cycles.
Primer System -
Figure
5
6
1. Check the oil level. See the
How To Check/Add Oil
section.
2. Push the stop switch (
A
), if equipped, to the on position (Figure 5).
3. Turn the fuel shut-off valve (
B
), if equipped, to the on position.
4. Move the throttle control (
C
) to the fast
position. Operate the engine in the fast
position.
5.
Push the red primer (
F
) three times.
Note:
Priming is usually unnecessary when restarting a warm engine.
Note:
If you push the primer too many times, excessive fuel will flood the carburetor
and the engine will be difficult to start.
6. Make sure equipment drive controls, if equipped, are disengaged. See the equipment
manual for location and operation of these controls.
7. If the product is equipped with an engine stop lever (
D
), hold the engine stop lever
against the handle (Figure 6).
8.
Rewind Start:
Firmly hold the starter cord handle (
E
). Pull the starter cord handle
slowly until resistance is felt, then pull rapidly (Figure 5).
Note:
If the engine does not start after three attempts, repeat Steps 6, 7, and 8. If it
still does not start, go to
BRIGGSandSTRATTON.COM
or call
1-800-233-3723
(in
USA).
WARNING:
Rapid retraction of the starter cord (kickback) will pull your
hand and arm toward the engine faster than you can let go. Broken bones,
fractures, bruises or sprains could result. When starting engine, pull the starter cord
slowly until resistance is felt and then pull rapidly to avoid kickback.
9.
Electric Start:
Turn the electric start switch to the on/start position. See the
equipment manual for the location and operation of the switch.
Note:
If the engine does not start after three attempts, repeat Steps 6, 7, and 9. If it
still does not start, go to
BRIGGSandSTRATTON.COM
or call
1-800-233-3723
(in
USA).
CAUTION:
To extend the life of the starter, use short starting cycles (five seconds
maximum). Wait one minute between starting cycles.
Choke System -
Figure
5
6
1. Check the oil level. See the
How To Check/Add Oil
section.
2. Push the stop switch (
A
), if equipped, to the on position (Figure 5).
3. Turn the fuel shut-off valve (
B
), if equipped, to the on position.
4. Move the throttle control (
C
) to the fast
position. Operate the engine in the fast
position.
5. Move the choke lever (
G
)
,
or the combination choke/throttle lever, to the
choke
position.
Note:
Choke is usually unnecessary when restarting a warm engine.
6. Make sure equipment drive controls, if equipped, are disengaged. See the equipment
manual for location and operation of these controls.
7. If the product is equipped with an engine stop lever (
D
), hold the engine stop lever
against the handle (Figure 6).
8.
Rewind Start:
Firmly hold the starter cord handle (
E
). Pull the starter cord handle
slowly until resistance is felt, then pull rapidly (Figure 5).
Note:
If the engine does not start after three attempts, go to
BRIGGSandSTRATTON.COM
or call
1-800-233-3723
(in USA).
WARNING:
Rapid retraction of the starter cord (kickback) will pull your
hand and arm toward the engine faster than you can let go. Broken bones,
fractures, bruises or sprains could result. When starting engine, pull the starter cord
slowly until resistance is felt and then pull rapidly to avoid kickback.
9.
Electric Start:
Turn the electric start switch to the on/start position. See the
equipment manual for the location and operation of the switch.
Note:
If the engine does not start after three attempts, go to
BRIGGSandSTRATTON.COM
or call
1-800-233-3723
(in USA).
CAUTION:
To extend the life of the starter, use short starting cycles (five seconds
maximum). Wait one minute between starting cycles.
10. As the engine warms up, move the choke control (
G
) to the run
position (Figure
5).
How To Stop The Engine -
Figure
5
6
WARNING
Gasoline and its vapors are extremely flammable and explosive.
Fire or explosion can cause severe burns or death.
•
Do not choke the carburetor to stop engine.
1. Release the engine stop lever lever (
A,
Figure 6)
or
Engine with Throttle Control:
Move the throttle control (
C,
Figure 5) to the stop
position
or
Engine with Stop Switch:
Push the stop switch (
A,
Figure 5) to the off position
or
Engine with Electric Start:
Turn the electric start switch to the off/stop position.
See the equipment manual for the location and operation of the switch.
2.
Engine with optional Fuel Shut-off:
After the engine stops, turn the fuel shut-off
valve (
B,
Figure 5) to the closed position.
Maintenance
Use only original equipment replacement parts. Other parts may not perform as
well, may damage the unit, and may result in injury.
In addition, use of other parts
may void your warranty.
We recommend that you see any Briggs & Stratton Authorized Dealer for all
maintenance and service of the engine and engine parts.
CAUTION:
All the components used to build this engine must remain in place for proper
operation.
Emissions Control
Maintenance, replacement, or repair of the emissions control devices and systems
may be performed by any non-road engine repair establishment or individual.
However, to obtain “no charge” emissions control service, the work must be performed
by a factory authorized dealer. See the Emissions Warranty.
Unintentional sparking can result in fire or electric shock.
Unintentional start-up can result in entanglement, traumatic amputation,
or laceration.
Fire hazard
WARNING
Before performing adjustments or repairs:
•
Disconnect the spark plug wire and keep it away from the spark plug.
•
Use only correct tools.
•
Do not tamper with governor spring, links or other parts to increase engine speed.
•
Replacement parts must be the same and installed in the same position as the
original parts.
•
Do not strike the flywheel with a hammer or hard object because the flywheel may
later shatter during operation.
When testing for spark:
•
Use approved spark plug tester.
•
Do not check for spark with spark plug removed.
Содержание Intek 825 Series
Страница 3: ...3 A A B 7 A B 8 A 9 B C 10 D E F 11 K 12 D C E A B A 13 A B C D D B C 14 B C A 15...
Страница 27: ...27 el 15 2 6 128 39 2 64742 47 8 1 800 424 9300 4442...
Страница 91: ...91...