77
9 Appendices
9.1 Video Quality Table
Using Brigade’s Resource calculator, the below tables have been compiled. Please note the following:
➢
The values below are for reference only
➢
Streaming bandwidth can vary considerably according to the level of variations in the image. Static images are more efficiently
compressed than dynamic ones
➢
Frame rates are assumed to be set to maximum which is 25fps for PAL and 30fps for NTSC
Quality level
1 (Highest)
2
3
4
5
6
7
8 (Lowest)
Video Streaming Data
Rate (Kbps) depending
on resolution (H.264)
1080P (AHD)
8192
6390
5505
4068
3712
2818
1919
1024
960P (AHD)
7987.2
6240
5366.4
4492.8
3619.2
2745.6
1872
998.4
720P (AHD)
6144
4800
4128
3456
2784
2112
1440
768
WD1
2662.4
1996.8
1664
1331.2
1170
1040
936
832
D1
2048
1536
1280
1024
900
800
720
640
WHD1
1996.8
1664
1331.2
998.4
832
728
650
585
HD1
1536
1280
1024
768
640
560
500
450
WCIF
1331.2
998.4
832
665.6
572
455
405.6
364
CIF (Lowest)
1024
768
640
512
440
350
312
280
Video Streaming Data
Rate (Kbps) depending
on resolution (H.265)
1080P (AHD)
5734
4473
3847
3221
2596
1970
1344
717
960P (AHD)
5591
4368
3756
3145
2533
1922
1310
699
720P (AHD)
4301
3360
2890
2419
1949
1478
1008
538
WD1
1597
1198
998
799
702
624
562
499
D1
1331
998
832
666
630
560
504
448
WHD1
1198
998
799
599
499
437
390
351
HD1
998
832
666
538
448
392
400
360
WCIF
799
599
499
399
343
273
243
218
CIF (Lowest)
717
538
448
358
352
280
250
224
9.2 Normal / Alarm Recording Parameters
Warning: The values shown below are for reference only.
For typical recording sizes for a one-hour duration and HDD recording times in hours versus storage capacity, please use the MDR storage
calculator:
https://brigade-electronics.com/mdr-hub/.
9.3 Software Compatibility Matrix
No.
Firmware Version
Client Version
Server Version
Compatibility
Comments
(1)
1
MDR 500 Series FW
MDR-Dashboard 5.0
MDR-Server 5.0
Yes
(2)
2
MDR 500 Series FW
MDR-Dashboard 5.0
MDR-Server 6.0
No
500 Series client cannot login 600 Series server.
(3)
3
MDR 500 Series FW
MDR-Dashboard 6.0
MDR-Server 5.0
No
600 Series client cannot login 500 Series server.
(4)
4
MDR 500 Series FW
MDR-Dashboard 6.0
MDR-Server 6.0
Yes
(5)
5
MDR 644 & 641 FW
MDR-Dashboard 5.0
MDR-Server 5.0
Yes, limitation
see comments
600 Series FMW is not fully compatible with 500
Series SW, the remote setting interface cannot
open, and the Evidence centre is not fully
compatible because of the metadata structure
change which will cause evidence loss. But local
mode features are still usable.
(6)
6
MDR 644 & 641 FW
MDR-Dashboard 5.0
MDR-Server 6.0
No
500 Series client cannot login 600 Series server.
(7)
7
MDR 644 & 641 FW
MDR-Dashboard 6.0
MDR-Server 5.0
No
600 Series client cannot login 500 Series server.
(8)
8
MDR 644 & 641 FW
MDR-Dashboard 6.0
MDR-Server 6.0
Yes
Notes:
•
iOS and Android apps: 600 Series apps only compatible with 600 Series server. 500 Series apps only compatible with 500 Series server.
•
Please ensure MDR-Server and MDR-Dashboard versions match
.
Additional Compatible List 1 for Upgrading/Downgrading Firmware
Item
FW Version Before
FW Version After
Compatibility
Remark
1
MDR 5.0 FW
MDR 6.0 FW
No
MDR 500 uses 5.0 FW, MDR 644 & 641 uses
6.0 FW, they are not compatible to each other.
2
MDR 6.0 FW
MDR 5.0 FW
No
Additional Compatible List 2 for Import Config File from Version to Version
Item
FW Version Before
FW Version After
Compatibility
Remark
1
MDR 5.0 FW
MDR 6.0 FW
No
Feature and OSD changed, previous config file
cannot be recognized or used by the new FW
2
MDR 6.0 FW
MDR 5.0 FW
No