http://192.168.1.105/ setpara[29]=1
Socket command text:
setpara[29]=1;
Cycle Switch Mode
Cycle switch mode changes the relay output status automatically on and off in customized
time period. After receiving cycle commands, relay output will always cycle until you give it
a new command.
Switches
To
pulse off
ch1 output, you can input by require web access:
Web access URL:
http://192.168.1.105/k01=6
Socket command text:
k01=6;
Timing Features
To set up customized timer for relay cycle outputs, timer T1 and T2 are used and need to
be set. Each relay channel has two independent timers K0xT1 and K0xT2, time period
supports from 1ms to 4294967295 second. K0xT1/K0xT2 is needed to be set for time
value, and K0xU1/K0xU2 is need to be set for timer value unit. Default value for
K0xT1/K0xT2 is 1000, and default unit for K0xU1/K0xU2 is ms.
To set timer T1 value to 5000:
Web access URL:
http://192.168.1.105/ setpara[65]=5000
Socket command text:
setpara[65]=5000;
To set timer T1 value unit to ms:
Web access URL:
http://192.168.1.105/ setpara[29]=0
Socket command text:
setpara[29]=0;