29 / 40
19 MAX/MIN indicator
20 Outdoor temperature
21 Battery level indicator (sensor)
22 Outdoor sensor signal strength indicator
23 HI/LO Alert
and Alarm on
24 Indoor indicator
25 Indoor humidity
26 MAX/MIN indicator
27 Indoor temperature
28 Battery level indicator (base station)
29 HI/LO Alert for humidity and Alarm on
30 HI/LO Alert for temperature and Alarm on
9 Before starting operation
NOTICE
Avoid connection faults!
In order to avoid connection problems between the devices, the following points must be observed
during commissioning.
1. Place the base unit (receiver) and sensor (transmitter) as close together as possible.
2. Connect the power supply to the base unit and wait until the indoor temperature is displayed.
3. Establish power supply for the sensor.
4. Set up/operate the base unit and sensor within the effective transmission range.
5. Make sure that the base unit and the radio sensor are set to the same channel.
When changing the batteries, always remove the batteries in both the base unit and the sensor and
reinsert them in the correct order so that the radio connection can be re-established. If one of the two
devices is operated via a mains power connection, the power connection for this device must also be
disconnected briefly when changing the battery. If, for example, only the batteries in the sensor are re-
placed, the signal cannot be received or can no longer be received correctly.
Note that the actual range depends on the building materials used in the building and the position of
the base unit and outdoor sensor. External influences (various radio transmitters and other sources of
interference) can greatly reduce the possible range. In such cases, we recommend finding other loca-
tions for both the base unit and the outdoor sensor. Sometimes a shift of just a few centimetres is
enough!
10 Setting up power supply
Basestation
1. Remove the battery compartment cover.
2. Insert the batteries into the battery compartment. Ensure that the battery polarity (+/-) is correct.
3. Replace the battery compartment cover.
4. Wait until the indoor temperature is displayed on the base station.
Remote sensor
5. Loosen the screws at the battery compartment cover with a small Philips screwdriver and remove
the cover.
6. Insert the batteries into the battery compartment. Ensure that the battery polarity (+/-) is correct.
7. Replace the cover and retighten it with the screw.
Battery replacement
8. Press the RESET button on the sensor after every battery change.
9. Press the SCAN button on the base station to re-establish pairing.
Содержание 7002530
Страница 1: ...Wetterstation Weather Station Professional Rain Gauge DE Bedienungsanleitung EN Instruction manual...
Страница 3: ...Deutsch 4 English 20...
Страница 10: ...10 40 7 Kippwaage 8 Regensensor 9 RESET Taste 10 Batteriefachdeckel...
Страница 26: ...26 40 7 Tipping bucket 8 Rain sensor 9 RESET button 10 Battery compartment...
Страница 36: ......
Страница 37: ......
Страница 38: ......
Страница 40: ...Bresser GmbH Gutenbergstra e 2 46414 Rhede Germany www bresser de BresserEurope Contact...