6
|
COOLER LOCATION
Check proposed cooler location to ensure it is structurally
capable of supporting the weight of the cooler. If the roof is
structurally inadequate, provide an alternate load bearing
structure.
The ideal location for the cooler is in a central position on the
roof (away from sleeping areas and where people spend most
of their time) so that the duct runs are of approximately the
same length. Carefully consider neighbouring residences and
noise levels when locating the cooler, if necessary talk to the
customer and the neighbour before carrying out the installation.
Always locate the cooler where it will receive adequate fresh air
and not in a recess where it may be starved for air or where the
air is polluted. Ensure that the cooler is installed such that the
fan is facing an unoccupied space.
Ensure location is a minimum of:
•
3m/10’ from a solid fuel heater flue,
•
1.5m/5’ from a gas flue,
•
5m/17’ from a sewer vent, and
•
600mm/2’ from a wall.
The cooler must be mounted at least 3m/10’ (preferably
5m/17’) away from any TV antenna or antenna cables.
Make sure the cooler is not between the antenna and the
transmission tower that is providing the television signal
to the home.
Allow adequate access to and around the cooler for
maintenance. Provision must be made for access to electricity,
water supplies and drains.
Note!
Do you need to discuss the installation of items like
safety anchor points with the customer?
ILL1150-A
ILL1155-C
ILL1155-C
Lift the venturi and fan assembly out of the cooler. Take care
with the motor lead, which will be sitting loosely in the bottom
of the cooler.
The venturi and fan assembly can be placed on to the ground
until the rest of the cooler has been installed on the dropper.
REMOVING THE TRANSITION
Turn the cooler onto its side to remove the transition.
There are clips in each of the four corners that will disengage
once the transition is given a firm pull.
If any of the corners are difficult to remove do not use
excessive force. Gently squeeze the clips together and
remove the transition one corner at a time.
REMOVING THE VENTURI
Once the pad frames have been removed, detach the venturi
and fan assembly.
Disengage the two venturi clips as shown.
Note!
Ensure the steel restraint cable and motor cable are
secured against the side of the venturi by the sticker provided.
X
x
ILL1150-A
ILL1093-E
Sticker securing cables