TBQ/TBS EVAPORATIVE COOLER INSTALLATION MANUAL
|
15
ILL1714-A
ILL1615-A
SETTING THE WATER LEVEL
cont
Turn on the mains water supply to the cooler.
Turn the cooler on at the Controller, in “COOL” mode.
Adjust set temperature slider to be close to current room
temperature so that fan speed remains low.
Allow the tank (reservoir) to fill with water. The float valve will
eventually stop the water from entering the cooler. Wait for this
to happen and check the water level.
ILL998-D
If the level is too high rotate the float clockwise. Drain some
water from the tank and allow it to refill to the new set point.
If too low rotate the float in an anti-clockwise direction. The
correct water level is approximately 5mm / 3/16” below the
surface of the tank the float valve is mounted on. It is advisable
to check the water level again after the float valve washer has
“bedded in”.
Cooler operating information is available from the ‘Service
Operating Screen’ under the COOLER tab of the SETTINGS
menu.
SETTING THE WATER LEVEL
Isolate power to the cooler electronics and disconnect the
pump, making sure the plug is kept away from any water. Turn
the power back on.
ILL1663-A
Once the water level is correct, isolate the control box and
connect the pump plug.
CONNECTING THE MAGIQTOUCH
CONTROLLER
®
Refer to the installation manual provided with the MagIQtouch
Controller for instructions on installing the controller.
The wall control cable plugs into the electronics module - (A).
(Refer diagram on previous page)
Coolers are supplied with a 20m / 66’ control cable. Longer
cable lengths are available from Seeley.
Note!
Where maximum recommended cable lengths are
exceeded, or cables are not routed in accordance with Seeley
recommendations, Seeley technical support may not be
available and the product warranty may be voided.
MAGIQTOUCH CONTROLLER
®
DISPLAY
INFORMATION
Diagnosis and cooler operating information can also be viewed
from the MagIQtouch Controller. Faults are displayed on the
screen as they occur.
ILL997-C
ILL1664-A
SETUP FOR BLEED FUNNEL
If you installed the bleed funnel instead of the drain valve then
the cooler will automatically be set to “NO DRAIN CONTROL”
provided that the shorting plug is installed correctly.
The “NO DRAIN CONTROL” setting can also be set manually
under the “COOLER” tab in the “WATER MANAGER” menu.