14
|
ILL1062-G
ILL1678-A
Connect the water sensor plug (D) and inlet solenoid plug
(C) as shown. If not using a water sensor, then ensure that a
shorting plug is fitted as provided.
CONNECTING THE WATER PUMP
Route the pump cord as shown.
Once the water level is set correctly, isolate the electronics
module and connect the pump plug (F).
Important!
Do not connect the pump plug until the water level
is set.
WARNING!
Do not run the pump while the pad frames are off
and the fan is on.
Once plugs are connected, switch the electronics module on.
Important!
Ensure the flexible splash protection cover is in place.
ILL1061-C
ILL1095-B
LEGEND
A - Control Cable
B - Speed Adjustment
C - Inlet Solenoid
D -
Water Sensor
or Shorting Plug
E - Drain Valve
F - Pump
G - Operation & Fault
code LED’s
Ensure the cables cannot rest in the water once the tank is filled
and plugs are connected in the correct orientation.
ILL1075-C
Route the drain valve cable as shown before connecting it
to the electronics module (E).
ELECTRICAL CONNECTION
cont