Breezair IWC05 Скачать руководство пользователя страница 6

ILL 1339-D

P

o

w

e

r

P

u

m

p

O

n

F

a

n

P

u

m

p

E

x

t

J6

J4

OUT

IN

F

1

F

2

1

2

3

4

5

1

2

3

4

5

C

o

m

In

1

In

2

In

3

In

4

C

o

m

O

u

t1

O

u

t2

O

u

t3

O

u

t4

S

.H

u

m

S

.T

e

m

p

OUT

IN

H

.E

S

P

1

F

a

u

lt

D

ra

in

J7

J5

H

D

D

T

1

2

3

4

5

1

2

3

4

5

C

o

m

In

5

In

6

In

7

In

8

C

o

m

O

u

t5

O

u

t6

O

u

t7

O

u

t8

1

2

3

4

5

All Commons connected

 to Negative

0V Ground

NPN

RJ11

RJ12

0V Ground

All Commons connected

 to Negative

Q2

Common

4-32VDC

<=12mAmps

CPMD

COMMS

REMOTE
SENSOR

D2

D1

Common

R2

1.4-32VDC
<=40mAmp

D3

Q1

J3

J2

R1

Input

RES-NTC

RL

Output

RL

R3

P/N 856315-B

INPUT

CONNECTION

OUTPUT

CONNECTION

(C) SEELEY INTERNATIONAL

 AUSTRALIA 2004

4-32VDC

1.4-32VDC

Industrial Wall Control Application Notes

55

5

 

60m

CPMD

 

   

 

HUB 1

 

HUB 2

 

SENSOR

Industrial Wall 

Industrial Wall 

Control

Control

SENSOR

 

CPMD

 

 

CPMD

 

 

CPMD

 

20m

.

                

Any length

OK up to combined
length of 140m from
IWC to CPMD.  

                

Any length

OK up to combined
length of 200m from
IWC to CPMD.  

 

60m

 

CPMD

CPMD

CPMD

CPMD

 

CPMD

 

 

 

 

 

max 40m !

max 40m !

max 40m !

max 40m !

max 40m !

max 40m !

max 40m !

max 120m !

max 120m !

max 140m !

!

Coolers are supplied with 20m data cable in 
accessories kit

!

Hubs are supplied with 20m data cable in kit.

!

Industrial Wall Controls (IWC) are supplied with 
20m Sensor cable in kit

!

60m Sensor cable on reel available

!

20m data cable in re-sealable bag available

!

40m data cable on reel available

!

60m data cable on reel available

!

80m data cable on reel available

!

100m data cable on reel available

!

4-way in-line joiners available to extend data cable 
to maximum lengths shown on diagram

!

Data cables may be shortened or lengthened (to 
maximums shown), using ONLY correct RJ 
connectors and crimping tools

!

Cables supplied by Breezair are 26AWG, 7/013, 4 
core & 6 core flat

!

ALWAYS route cables at least 300mm away from 
regular power cables and high power machines.  
Cross over power cables at right angles.

!

Where maximum data cable and sensor cable 
lengths are exceeded, or cables are not routed in 
accordance with our recommendations Seeley 
technical support is not available and the product 
warranty may be voided.

Breezair Control System

Cable Lengths

Industrial Wall Control

824130-A

0703

MASTER

MASTER

MASTER

SLAVE 1

SLAVE 1

SLAVE 2

SLAVE 3

SLAVE 3

SLAVE 2

                

Any length

OK up to combined
length of 200m from
IWC to CPMD.  

 

 

 

 

 

 

 

 

 

 

Содержание IWC05

Страница 1: ...Application Notes Application Notes Industrial Wall Control IWC05...

Страница 2: ...control of the cooler functions in the MANUAL Man mode The IWC05 may also be set up to control the Air Cooler from EXTERNAL devices such as PLCs and Building Management System computers In this case t...

Страница 3: ...ive voltage is applied when there is no voltage on Input 2 With Input Fan1 and Fan2 positive the cooler will run at maximum speed Input 4 Pump Pump ON OFF This input enables the pump to run when a pos...

Страница 4: ...onsider a Temperature of 20 3 C the bit stream will be 0000000 011001011 Therefore read as 20 3 C 203 Output 8 Drain Drain Control Output This output is activated whenever the Drain Valve is open It w...

Страница 5: ...lue in binary is 10 x the Temperature reading for example 20 6 C is sent as a value of 206 The below example shown at 1sec div is 44 RH which is 00101100 in binary The bit format is S L H D L H D L H...

Страница 6: ...plied with 20m data cable in accessories kit Hubs are supplied with 20m data cable in kit Industrial Wall Controls IWC are supplied with 20m Sensor cable in kit 60m Sensor cable on reel available 20m...

Страница 7: ...eezair coolers to various downstream systems the air flow performance curves are provided below Breezair TBA 550 Airflow Industrial wall control speed settings for External fan speed inputs 0 20 40 60...

Страница 8: ...828534 D 0705 ILL1331 A...

Отзывы: