Output 2 [Fan] - Fan ON / OFF

This output is activated whenever the air cooler fan has been turned ON.

Output 3 [Pump] - Pump ON / OFF

This output is activated whenever the air cooler pump has been turned ON.

Output 4 [Ext] - External Control

This output is activated whenever the air cooler is under external control.  

Output 5 [Fault] - Fault ON / OFF

This output is activated whenever the air cooler is in a fault condition. Refer to Installation and Operation manual, 
SERVICE [SERVICE] Mode, page 8

 

for more details about faults.  

Output 6 [S.Hum] - Serial Humidity

This output is activated whenever the air cooler has been turned ON or is in Standby Mode. The binary information 
represents humidity as a percentage. The bit stream is described on page 4. 
For example, consider a relative humidity of 32%, the bit stream will be: -

00000000{00100000}

Therefore read as 32%RH

       32

Output 7 [S.Temp] - Serial Temperature

This output is activated whenever the air cooler has been turned ON or is in Standby Mode. The binary data 
represents 10 x Temperature (in 

°

C). The bit stream is described on page 4. 

For an example, consider a Temperature of 20.3

°

C the bit stream will be: -

0000000{011001011}

Therefore read as 20.3

°

C

     

203

Output 8 [Drain]  Drain Control Output

This output is activated whenever the Drain Valve is open. It will activate only after the time delay period set in the 
IWC05 Program. The output will remain activated while the Drain valve is open. If the Drain valve opens for a 
period of time less than the delay time set, the output signal will remain activated for 5 seconds only.

OUTPUT CONFIGURATION

IWC05 outputs 1,2,3,4,5 & 8 are switches only. They will function when 
connected to a power supply from an external source of (1.4 - 32VDC at 
40mA load). 
Connect the external DC power supply to the load, connect the negative of 
the load to the desired output terminal and connect the negative of the 
power supply to the common [com] terminal on the IWC05. The output will 
then turn on your load as desired (page 4).

Outputs

All outputs are indicators only of the state of the air cooler. None of them 
are monitored for integrity. A fault on an output line is not indicated in the 
IWC05. 

Output 1 [ON] - System ON / OFF

This output is activated whenever the Air Cooler has been turned ON  from 
any source, in any mode. 

Industrial Wall Control Application Notes

4

J6

OUT1

OUT2

OUT3

OUT4

COM

ILL1346-A

33

Содержание IWC05

Страница 1: ...Application Notes Application Notes Industrial Wall Control IWC05...

Страница 2: ...control of the cooler functions in the MANUAL Man mode The IWC05 may also be set up to control the Air Cooler from EXTERNAL devices such as PLCs and Building Management System computers In this case t...

Страница 3: ...ive voltage is applied when there is no voltage on Input 2 With Input Fan1 and Fan2 positive the cooler will run at maximum speed Input 4 Pump Pump ON OFF This input enables the pump to run when a pos...

Страница 4: ...onsider a Temperature of 20 3 C the bit stream will be 0000000 011001011 Therefore read as 20 3 C 203 Output 8 Drain Drain Control Output This output is activated whenever the Drain Valve is open It w...

Страница 5: ...lue in binary is 10 x the Temperature reading for example 20 6 C is sent as a value of 206 The below example shown at 1sec div is 44 RH which is 00101100 in binary The bit format is S L H D L H D L H...

Страница 6: ...plied with 20m data cable in accessories kit Hubs are supplied with 20m data cable in kit Industrial Wall Controls IWC are supplied with 20m Sensor cable in kit 60m Sensor cable on reel available 20m...

Страница 7: ...eezair coolers to various downstream systems the air flow performance curves are provided below Breezair TBA 550 Airflow Industrial wall control speed settings for External fan speed inputs 0 20 40 60...

Страница 8: ...828534 D 0705 ILL1331 A...

Отзывы: