BRAVE Steel
–
User and service manual 39
Example:
Command for switching on 2 relays 1 impulse is for example
*8
, the command for
disconnection is
*8
and the command for switching on 2 relays 2 impulses is
*9
.
Programming:
352*8
♫ ,
432*8
♫ ,
362*9 ♫
.
If you are in conversation with the Brave, the command to open a gate would be button
9
, the first impulse starts and the gate opens, the second impulse stops it, the time the
gate is opened "opened space" is set by time between the impulses (
parameter 30
)
after people enter press
8
, then Brave makes 1 impulse and disconnects, gate closes.
Parameter
Value
Meaning
Basic
37
r ss
time
ss
[sec] of relay
r
on for time
t1/t4
(01-99)
105 205
r
– relay number [1-2]
ss
– time t1 / t4 for which relay 1 / 2 is switched on [2 spaces 00-99], where
time 00 means 0,5sec
Parameter
Value
Meaning
Basic
38
r p
relay
r
control during incoming call
(0/1)
11 21
r
– relay number [1-2]
p
– parameter whether it is allowed
p=1
or disallowed
p=0
to control relay
during incoming call.
To prohibit „control‟ during an incoming call, for use with relay 2 in mode 1 for
controlling a garage door, so the electronics open the garage door and the car
passing through the door, closes the door. Then control from the phone could
result in a permanently opened door (i.e. the door doesn‟t close because car
didn‟t enter).
Parameter
Value
Meaning
Basic
39
xx
time
xx
[sec] between switching on relays
1 and 2 in regime m=5 - time
t3
(01-99)
10
xx
– time t3 between switching on relays 1 and 2 when regime
m=5
is set
(gradual opening) [2 spaces 00-99] ], where time 00 means 0,5sec
Parameter
Value
Meaning
Basic
30
r zz
time
zz
[sec] between impulses for
switching on relay
r
2 impulses- time
t2/t5
(01-99)
105 205
r
– relay number [1-2]
zz
– time t2 / t5 between first and second impulse for switching on relay 1 / 2
[2 spaces 00-99], where time 00 means 0,5sec