Maintenance and Care 

Water Damage 

Water damage invalidates the guarantee. 

If  the  instrument  suffers  water  damage,  proceed  as  follows.    Remove  the  batteries  at 
once.  Rinse  the  instrument  with  fresh  warm  water.    Dry  the  instrument  (e.g.  warm  air, 
hair  dryer).  Send  the  instrument,  as  soon  as  possible,  to  your  BRÄUNIGER  GMBH 
dealer or direct to BRÄUNIGER GMBH for testing. 
 

Warning

: NEVER dry the instrument in a microwave oven. 

 

Malfunction 

Should you have a problem when running the instrument, remove the batteries for five 
minutes. When the batteries are returned, the instrument carries out a self test. 
If  the  problem  persists  send  the  instrument,  with  a  description  of  the  problem,  to  your 
BRÄUNIGER GMBH dealer or direct to BRÄUNIGER GMBH. 
 

Guarantee Limitation

In rare cases it may happen that the instrument does not provide any data at all, or the 
data  is  incorrect.  BRÄUNIGER  GMBH  is  not  responsible  for  any  damages  due  to  the 
incorrect functioning of the instrument. 

Responsibility for ensuring safe flight lies with 

the pilot alone.

 

 
 

Technical Data 

Size:                                       138 x 74 x 23 mm  ( 4-3/8 x 2-3/4 x 13/16 inches ) 

Weight:                                   178 grams  ( 6.278 ounces ) with 2 alkaline batteries, 

without mountings 

Power Supply:                         2 x AA alkaline batteries or NiMH batteries 

Battery Life:                             >250 hours with 2 alkaline batteries 

Altimeter:                                 max 11,500 m  (37,700 feet ), 1 m  ( 3 ft ) steps 

Variometer:                             analog ± 10 m/s ( 2,000 ft/min ), 0.2 m/s, ( 40 ft/min) steps  

                                                digital ± 96 m/s (19,200 ft/min), 0.1 m/s steps (10 ft/min ) 

Integrator (Vario Averager):    adjustable from 1 sec to 30 sec 

Speed Display:                        digital 0 to 160 km/h  ( 99 mph ) 

                                                displayed in km/h, kts or mph 

                                                resolution: 1 mph, 1 km/h or 1 kts 

                                                calibration range ± 50% 

Temperature Display:              -50°C to 76°C  ( -72.4°F to 168.8°F) 

Содержание IQ-ONE

Страница 1: ...Br uniger IQ ONE IQ ONE with flight recorder Br uniger GmbH Dr Karl Slevogt Str 5 D 82362 Weilheim www brauniger com...

Страница 2: ...T1 7 Option Mode ALT1 8 Set Mode ALT2 8 Option Mode ALT2 9 Variometer 10 Analogue Vario Beam Display 10 Direct functions 10 Set Mode 11 Option Mode 11 Sink Alarm 13 Direct functions 13 Set Mode 13 Opt...

Страница 3: ...coustic signal main Variometer ON OFF of the sink warning alarm main sink alarm warning change of height displays main altimeter reset height difference main altimeter START STOP of stop watch main ti...

Страница 4: ...ments of the Display Acoustics keys Change Value keys Height and Memo keys Analogue vario Integrated digital Vario Speed or Temperature Barometric Height 1 or Height 2 Relative Height 3 Time Functions...

Страница 5: ...the date The analog scale on the left shows the battery charge Switching Off To switch the instrument OFF without setting the time Press and hold the TIME CHRONO MEMO Key for about seven seconds Durin...

Страница 6: ...e Sink alarm On Off Audio Sink alarm setting Setting point with keys Unit TEMP C F Corr Temp Correct Sensor 8 0 to 7 9 Unit Speed km h kts mph StALL Stall speed Corr SPEED Correct Speed 50 100 150 SPE...

Страница 7: ...nce air pressure On a stable day temperature induced differences of 1mb mean a height difference of 10 metres Depending on the weather air pressure at sea level QNH may vary from 950 mb to 1050 mb In...

Страница 8: ...e ALT3 was last reset or since the instrument was switched on Press Clear ALT3 the Down Arrow Key to set this number back to 0 Set Mode ALT1 Press the Altitude Key for three seconds during ALT1 displa...

Страница 9: ...rrections can be made in this mode This may become necessary when the pressure sensor after several years use is no longer exact The maximum correction possible is 47 9 hPa A short press of the Altitu...

Страница 10: ...ode ALT1 and ALT2 are of equal size You can set one of the values to feet TIP To view your current altitude in both meters and feet change this option to ABS and set the units for ALT2 to m In Run Mod...

Страница 11: ...ls 0 2 m s Up to 5 m s the beam fills up from the centre When the climb exceeds 5 m s the climb is displayed in reverse e g the display at 5 m s is full and it begins to clear from the middle Direct f...

Страница 12: ...n Mode Further long pressure on this key in the Set Mode brings the instrument into Option Mode Option 1 Unit Set units Set the required unit for the Vario display here The options are m s or ft minx1...

Страница 13: ...frequency Start of audio output Option 5 ASI Audio Scale Indication The audio scale indicator can be set to on or off ON OFF The audio scale indicator switches the rate of the peep tone from 50 50 to...

Страница 14: ...ressure on this key in the Set Mode brings the instrument into Option Mode Option 1 Unit The units of temperature can be set here There is a choice between C or F Option 2 Corr Temperature Correction...

Страница 15: ...on is necessary when you are under the impression that the displayed speed is incorrect The accuracy of the speed displayed is greatly influenced by the mounting position of the speed sensor therefore...

Страница 16: ...ing of the TIME CHRONO MEMO key called TIME key in future changes the time stop watch and memory displays When in Time or Chrono display a short press on the START STOP RESET key starts the stop watch...

Страница 17: ...date can be set here using the arrow keys Pressing the TIME key briefly allows you to choose which values to set This data is not visible on the startup page Note Starting to switch off the instrument...

Страница 18: ...was recorded for this flight too Date of flight Flight time Battery volume and sink alarm display independent of record flight Memo Set Mode IQ ONE Further long pressure on the TIME key brings the ins...

Страница 19: ...ight difference of more than plus or minus 30m has been recognized and the recorded flying time is more than 2 minutes A new flight is started when leaving Set or Option Mode and no flight acceptance...

Страница 20: ...ok flight number 2 will be suggested and so on until a flight with a barogram appears that can be deleted No single flights can be deleted directly from the log book Barograms recorded later in the lo...

Страница 21: ...n parameters Batteries 2 x Alkaline Type size AA 1 5V or 2 x rechargeable NiCd or NiMh accu size AA1 2 V Error messages Lo Batt Battery voltage less than 2 1 V Please change batteries Lo Temperature i...

Страница 22: ...to BR UNIGER GMBH Guarantee Limitation In rare cases it may happen that the instrument does not provide any data at all or the data is incorrect BR UNIGER GMBH is not responsible for any damages due t...

Страница 23: ...r automatic logging Max Barograph Recording 130 hours flying time Time IQ ONE recording interval 1 sec 5 sec or 15 sec recording of altitude altitude and speed or altitude and temperature Number of Lo...

Отзывы: