background image

14                                       Operating Instructions IQ-ONE / IQ-ONE+ 

Bräuniger GmbH 

 

Option 3 Unit 

 ( Set speed units ) 

 
Units for the speed display are chosen here. The choices are 
km/h or kts and mph. 
 
 
 
 
 

Option 4 Stall  

( Stall Speed ) 

 
The stall alarm sounds when flying too slowly results in an 
interruption to the laminar flow. 
 
The stall alarm can be switched off (value shows 0 km/h), or 
can be set from 10 km/h upwards. 
 
 

Option 5 Corr Speed 

( air speed correction ) 

A wing wheel sensor is used as a speed indicator (can be 
bought separately). 
 
Speed correction is in %. This correction is necessary when 
you are under the impression that the displayed speed is 
incorrect.  The accuracy of the speed displayed is greatly 
influenced by the mounting position of the speed sensor, 
therefore, you should take care when installing the wing wheel 
sensor.  Inaccuracy of the wing wheel sensor can be due to 
the production process in the range of  +2.5% (industry 
standard).  
 

Option 6 Speed Disp 

Speed Display 

 
Speed Disp shows if, and after what time lapse, change from 
speed to temperature display takes place. 
 
The following can be chosen: 

 

 

- speed only 

 

- change after 30 seconds 

 

- change after 60 seconds 

 

 

 

- change after 120 seconds 

 
The temperature display appears for 4 seconds.  If no speed 
sensor is switched on, only temperature is displayed. 
 
 
 

Содержание IQ-ONE

Страница 1: ...Br uniger IQ ONE IQ ONE with flight recorder Br uniger GmbH Dr Karl Slevogt Str 5 D 82362 Weilheim www brauniger com...

Страница 2: ...T1 7 Option Mode ALT1 8 Set Mode ALT2 8 Option Mode ALT2 9 Variometer 10 Analogue Vario Beam Display 10 Direct functions 10 Set Mode 11 Option Mode 11 Sink Alarm 13 Direct functions 13 Set Mode 13 Opt...

Страница 3: ...coustic signal main Variometer ON OFF of the sink warning alarm main sink alarm warning change of height displays main altimeter reset height difference main altimeter START STOP of stop watch main ti...

Страница 4: ...ments of the Display Acoustics keys Change Value keys Height and Memo keys Analogue vario Integrated digital Vario Speed or Temperature Barometric Height 1 or Height 2 Relative Height 3 Time Functions...

Страница 5: ...the date The analog scale on the left shows the battery charge Switching Off To switch the instrument OFF without setting the time Press and hold the TIME CHRONO MEMO Key for about seven seconds Durin...

Страница 6: ...e Sink alarm On Off Audio Sink alarm setting Setting point with keys Unit TEMP C F Corr Temp Correct Sensor 8 0 to 7 9 Unit Speed km h kts mph StALL Stall speed Corr SPEED Correct Speed 50 100 150 SPE...

Страница 7: ...nce air pressure On a stable day temperature induced differences of 1mb mean a height difference of 10 metres Depending on the weather air pressure at sea level QNH may vary from 950 mb to 1050 mb In...

Страница 8: ...e ALT3 was last reset or since the instrument was switched on Press Clear ALT3 the Down Arrow Key to set this number back to 0 Set Mode ALT1 Press the Altitude Key for three seconds during ALT1 displa...

Страница 9: ...rrections can be made in this mode This may become necessary when the pressure sensor after several years use is no longer exact The maximum correction possible is 47 9 hPa A short press of the Altitu...

Страница 10: ...ode ALT1 and ALT2 are of equal size You can set one of the values to feet TIP To view your current altitude in both meters and feet change this option to ABS and set the units for ALT2 to m In Run Mod...

Страница 11: ...ls 0 2 m s Up to 5 m s the beam fills up from the centre When the climb exceeds 5 m s the climb is displayed in reverse e g the display at 5 m s is full and it begins to clear from the middle Direct f...

Страница 12: ...n Mode Further long pressure on this key in the Set Mode brings the instrument into Option Mode Option 1 Unit Set units Set the required unit for the Vario display here The options are m s or ft minx1...

Страница 13: ...frequency Start of audio output Option 5 ASI Audio Scale Indication The audio scale indicator can be set to on or off ON OFF The audio scale indicator switches the rate of the peep tone from 50 50 to...

Страница 14: ...ressure on this key in the Set Mode brings the instrument into Option Mode Option 1 Unit The units of temperature can be set here There is a choice between C or F Option 2 Corr Temperature Correction...

Страница 15: ...on is necessary when you are under the impression that the displayed speed is incorrect The accuracy of the speed displayed is greatly influenced by the mounting position of the speed sensor therefore...

Страница 16: ...ing of the TIME CHRONO MEMO key called TIME key in future changes the time stop watch and memory displays When in Time or Chrono display a short press on the START STOP RESET key starts the stop watch...

Страница 17: ...date can be set here using the arrow keys Pressing the TIME key briefly allows you to choose which values to set This data is not visible on the startup page Note Starting to switch off the instrument...

Страница 18: ...was recorded for this flight too Date of flight Flight time Battery volume and sink alarm display independent of record flight Memo Set Mode IQ ONE Further long pressure on the TIME key brings the ins...

Страница 19: ...ight difference of more than plus or minus 30m has been recognized and the recorded flying time is more than 2 minutes A new flight is started when leaving Set or Option Mode and no flight acceptance...

Страница 20: ...ok flight number 2 will be suggested and so on until a flight with a barogram appears that can be deleted No single flights can be deleted directly from the log book Barograms recorded later in the lo...

Страница 21: ...n parameters Batteries 2 x Alkaline Type size AA 1 5V or 2 x rechargeable NiCd or NiMh accu size AA1 2 V Error messages Lo Batt Battery voltage less than 2 1 V Please change batteries Lo Temperature i...

Страница 22: ...to BR UNIGER GMBH Guarantee Limitation In rare cases it may happen that the instrument does not provide any data at all or the data is incorrect BR UNIGER GMBH is not responsible for any damages due t...

Страница 23: ...r automatic logging Max Barograph Recording 130 hours flying time Time IQ ONE recording interval 1 sec 5 sec or 15 sec recording of altitude altitude and speed or altitude and temperature Number of Lo...

Отзывы: