Page 38
Floor Level Guideline Adjustments
Sys
t
e
m
s
D
escr
i
p
ti
o
n
s
Vertical Arm
Stop Block
Must make full contact
.
Gap
not permitted
.
Wrong
OK
Stop blocks
must make
full contact
with the
edge of the vertical arms.
D
E
Improper microswitch
adjustment may
result in serious
bodily injury and/or
property damage.
WARNING
Photo E shows the lift with an incorrect Unfold/Down
microswitch setting which prevents the platform from
fully unfolding (stop blocks not making full contact with
vertical arms). Adjust microswitches as outlined on
page 37.
The bridge plate should be positioned so that the
outboard edge rests solidly on the platform UHMW
slides when at floor level as shown in Photo F. With
these conditions met, slightly raise or lower platform to
provide a smooth (level) transition between the plat-
form, bridge plate and the base plate (shown in Photo
F). Photo G shows lift with the Up/Fold microswitch
set too low which causes a gap between bridge plate
and platform.
Floor Level Guideline
for
Fixed
Inboard
Roll Stop (
Non-IB
) Lift Models
:
F
G
Wrong
OK
Bridge plate
must be level
and
must rest fully on UHMW slides
.
Gap
not permitted
.
Platform
too low
.
Stop Block Guideline
All Lift Models
Microswitches should be
adjusted so that the
platform is fully unfolded
allowing the stop blocks to
make full contact with the
inboard vertical edge of
the vertical arms (see
Photo D).
Failure to do
so can damage the lift
.