Bradley Terreon Quadra-Fount MF2944/BIR3 Скачать руководство пользователя страница 9

Installation 

MF2944/BIR3

Bradley • 

2215-1373 Rev. P; ECN 14-00-006 6/6/2014  9 

LOWER

BRACKET

FRONT

PANEL

SCREW

UPPER

BRACKET

7

Check Operation

A

Check to make sure both stops are fully 
open (see page 6) .

B

Turn on the main water supply to the 
Quadra-Fount and check for leaks .

C

Turn on the electrical power and pass 
your hand in front of each sensor until air 
is purged from the lines .

This valve is NOT factory preset. Upon installation, the 
temperature of this valve must be checked and adjusted 
to ensure delivery of a safe water temperature. Water in 
excess of 110°F (43°C) may cause scalding.

H

C

D

Loosen Cap Screw about ¼" (4-6 turns) 
and lift up cover (do not remove) .

E

Using cover, turn cartridge gently until 
desired water temperature is reached . Do 
not turn past stops as this may damage 
unit . Push cover down and tighten screw . 

8

Install Top Cover and Front Panel

A

Carefully place the top cover with 
threaded rods on top of washfountain 
sprayhead .

B

Inside the pedestal assembly of the 
washfountain (use front access), slide 
the anchor plate onto the threaded rods 
and secure anchor plate against bowl 
using the wing nuts provided .

C

To install front panel, slip slot in bottom 
of front pedestal panel over the lip on the 
lower bracket,

D

Secure panel to upper bracket with 
attached screw .

Содержание Terreon Quadra-Fount MF2944/BIR3

Страница 1: ...reater than 80 psi Make sure that all water supply lines have been flushed and then completely turned off before beginning installation Debris in supply lines can cause valves to malfunction Hardware...

Страница 2: ...valve allowing each user to activate a single flow of water Each valve uses less than half the maximum amount of hot water allowed by the ANSI ASHRAE IES 90A 1980 Standard Barrier free and ADA complia...

Страница 3: ...S45 2731 optional Stop Hose Valve Assembly with Two Mounting Screws MOUNTING PANELS LOWER BRACKET Parts included with the Quarda Fount Separate all parts from packaging materials and ensure you have a...

Страница 4: ...6 OBC 3 1 8 79 JUV 9 1 2 241 STD 8 1 2 216 OBC 5 1 2 140 JUV 5 127 Finished Floor 1 2 Nominal Copper Tubing For Supplies Stub Out Min 1 1 2 from Wall 7 1 2 191 19 1 2 495 1 1 2 NPT Waste Connection Fo...

Страница 5: ...ssembly to the wall using appropriate lifting procedures and align the locating notches on the mounting panel with the centerline marked on the wall If the floor is not level install shims under the l...

Страница 6: ...s on the side of the left pedestal panel Do not thread the screw completely into the panel but allow 5 16 of the screw to be exposed D Connect the other end of each supply hose to the Navigator TMV va...

Страница 7: ...two 3 8 bolts and washers supplied by installer G Fasten the bowl to the upper bracket on the pedestal assembly with the two 1 4 20 x 1 2 round head screws and 5 16 I D washers supplied H Install the...

Страница 8: ...right center station to the circuit board attached to the solenoid with the black supply tube D Connect the sensor cable from the left center hand station to the circuit board attached to the solenoid...

Страница 9: ...Water in excess of 110 F 43 C may cause scalding H C D Loosen Cap Screw about 4 6 turns and lift up cover do not remove E Using cover turn cartridge gently until desired water temperature is reached D...

Страница 10: ...ey recommends additional care and maintenance for the darker colored Terreon For complete instructions on this additional maintenance see Bradley document 1505 Do not use strong acid or alkaline chemi...

Страница 11: ...roducts leave a protective coating that helps prevent future smears and fingerprints Grease and Oil To remove grease and oil use a quality commercial detergent or caustic cleaner Apply in accordance t...

Страница 12: ...he battery plug from the adjacent working valve to the problem valve Wait for ten seconds Activate the problem station s sensor ten times The station should turn on If the station turns on and cycles...

Страница 13: ...8 307A Valve Body Thru 2 1 269 983 Diaphragm 3 1 269 577 Armature 4 1 269 578 Spring 5 1 269 1729 Armature Housing 6 1 269 1730 Clamp Armature Housing 7 1 269 579 Coil Solenoid Valve 8 3 160 447 Screw...

Страница 14: ...ater temperature or temperature fluctuation Hot water supply is not 10 above desired set point Increase hot water supply temperature Valve temperature is not properly set Adjust the temperature as sho...

Отзывы: