Before attempting to troubleshoot the valve or disassemble the components, check for the following conditions:

•  If stop valves are used, make sure that they are fully open.
•  Make sure that the hot and cold inlet pipes are connected properly, and that there are no cross-connections or 

leaking stop valves.

•   Check the hot water heater output to make sure that it is at least 10° F above the set temperature.

Thermostatic Mixing Valve Troubleshooting

Be sure to close the appropriate shut-off valves prior to disassembly of the valve and reopen the valves after inspection 

and repair is complete.

Problem

Cause

Solution

External leaks.

Damaged cartridge or O-rings.

Replace cartridge with part number 269-1927

Improper water 
temperature or 
temperature 
fluctuation.

Hot water supply is not 10° above desired set point.

Increase hot water supply temperature

Valve temperature is not properly set.

Adjust the temperature as shown on page 9 step 7 .

Limited water 
flow.

Dirt and debris have built up in the valve or strainer.

1 . Check to make sure both hot and cold supplies are 
connected to the Navigator mixing valve and that they 
have water flow .

2 . Remove cover and U-clip . Remove the cartridge and 
clean the strainer . It is not required to grease cartridge, 
however if desired, use silicone grease only . Do not use 
grease on check valves .

 

Tempered Line Adapter Option 

Part no. S39-804

(replaces S59-4000 if tempered line 
is used)

Strainer 

(173-028)

Parts List

Item

Part No.

Description

Quantity

S59-4000

1

160-463

Cap Screw

1

2

107-582

Cover

1

3

269-1927

Thermostatic Cartridge

1

4

198-014

Check Valve*

2

5

132-051

Retaining Ring*

2

6

118-319

Valve Body

1

7

146-079

U-Clip

1

* Included with Prepack S65-326

1

2

3

4

5

4

5

7

6

Содержание Terreon Quadra-Fount MF2944/BIR3

Страница 1: ...reater than 80 psi Make sure that all water supply lines have been flushed and then completely turned off before beginning installation Debris in supply lines can cause valves to malfunction Hardware...

Страница 2: ...valve allowing each user to activate a single flow of water Each valve uses less than half the maximum amount of hot water allowed by the ANSI ASHRAE IES 90A 1980 Standard Barrier free and ADA complia...

Страница 3: ...S45 2731 optional Stop Hose Valve Assembly with Two Mounting Screws MOUNTING PANELS LOWER BRACKET Parts included with the Quarda Fount Separate all parts from packaging materials and ensure you have a...

Страница 4: ...6 OBC 3 1 8 79 JUV 9 1 2 241 STD 8 1 2 216 OBC 5 1 2 140 JUV 5 127 Finished Floor 1 2 Nominal Copper Tubing For Supplies Stub Out Min 1 1 2 from Wall 7 1 2 191 19 1 2 495 1 1 2 NPT Waste Connection Fo...

Страница 5: ...ssembly to the wall using appropriate lifting procedures and align the locating notches on the mounting panel with the centerline marked on the wall If the floor is not level install shims under the l...

Страница 6: ...s on the side of the left pedestal panel Do not thread the screw completely into the panel but allow 5 16 of the screw to be exposed D Connect the other end of each supply hose to the Navigator TMV va...

Страница 7: ...two 3 8 bolts and washers supplied by installer G Fasten the bowl to the upper bracket on the pedestal assembly with the two 1 4 20 x 1 2 round head screws and 5 16 I D washers supplied H Install the...

Страница 8: ...right center station to the circuit board attached to the solenoid with the black supply tube D Connect the sensor cable from the left center hand station to the circuit board attached to the solenoid...

Страница 9: ...Water in excess of 110 F 43 C may cause scalding H C D Loosen Cap Screw about 4 6 turns and lift up cover do not remove E Using cover turn cartridge gently until desired water temperature is reached D...

Страница 10: ...ey recommends additional care and maintenance for the darker colored Terreon For complete instructions on this additional maintenance see Bradley document 1505 Do not use strong acid or alkaline chemi...

Страница 11: ...roducts leave a protective coating that helps prevent future smears and fingerprints Grease and Oil To remove grease and oil use a quality commercial detergent or caustic cleaner Apply in accordance t...

Страница 12: ...he battery plug from the adjacent working valve to the problem valve Wait for ten seconds Activate the problem station s sensor ten times The station should turn on If the station turns on and cycles...

Страница 13: ...8 307A Valve Body Thru 2 1 269 983 Diaphragm 3 1 269 577 Armature 4 1 269 578 Spring 5 1 269 1729 Armature Housing 6 1 269 1730 Clamp Armature Housing 7 1 269 579 Coil Solenoid Valve 8 3 160 447 Screw...

Страница 14: ...ater temperature or temperature fluctuation Hot water supply is not 10 above desired set point Increase hot water supply temperature Valve temperature is not properly set Adjust the temperature as sho...

Отзывы: