![Bradley Terreon Quadra-Fount MF2944/BIR3 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/bradley/terreon-quadra-fount-mf2944-bir3/terreon-quadra-fount-mf2944-bir3_installation-manual_2800368006.webp)
MF2944/BIR3
Installation
6
6/6/2014
Bradley •
215-1373 Rev. P; ECN 14-00-006
4
Install Solenoid Assembly
The letter "H" on the Navigator
®
mixing
valve indicates hot water supply inlet.
A
Attach the stops to hot and cold water rough-ins .
B
Connect one end of each supply hose to the stops .
C
Inside the pedestal, install the two 1/4" - 20 x
1/2" screws (supplied with valve assembly) in the
mounting holes on the side of the left pedestal panel .
Do not thread the screw completely into the panel,
but allow
5
/16" of the screw to be exposed .
D
Connect the other end of each supply hose to the
Navigator
®
TMV valve assembly (one on the hot side,
one of the cold side) .
E
Mount the valve bracket to the left side of the
pedestal .
F
For optional single tempered supply: attach the
stop to the 1/2" tempered supply line . Connect
the stop to the solenoid valve assembly with the
flexible supply hose .
1/4" - 20 x 1/2"
Screws
Solenoid Valve
Assembly
Navigator TMV
Supply Hose
Stop
Cold Supply
Inlet
Hot Supply
Inlet