Installation
TDB3104, WF3204
Bradley
• 215-1332 Rev. V; ECN 12-00-004
1/15/2013
11
Unit with "A" Drain and IR Module Shown,
Also Available with "O" Drain
Restraining Bracket
(140-128)
Top
Cover
Soap
Dispenser
8-5/8"
Tie Rod
Spacer
Coupling Nut
and Set Screw
Module
Cover
4-1/4" Tie Rod
(176-118)
IR Module
Assembly
Coupling Nut
and Set Screw
21-5/8" Tie Rod
(176-008A)
Tie Bar
Sprayhead
(S05-054B)
Support Tube
6
Electrical connections for Adaptive Infrared
START-UP NOTE: Do not use for two minutes after making
power connection. The sensors will take up to eight minutes
(without being used) to adapt to the bowl if another object is
detected during the two-minute start-up period.
A
Attach infrared female connect wire from infrared
module to solenoid.
B
Attach the infrared male connect wire from the
infrared module to the transformer lead wire.
C
Attach the remaining transformer lead wire to the
solenoid.
D
Connect 24 VAC transformer provided to power
source.
G
Pass your hand in front of each sensor until air is
purged from the lines.
Infrared Module
(S50-367)
Solenoid
Valve
I.R. Valve with
Thermostatic Mixing Valve
(Shown) (S45-2504)
24 VAC
Transformer
(S83-134)
Female
Connect
Male
Connect
Infrared
Module Female
Connect Wire
E
Turn supplies on. Open stop valves completely.
F
Open volume control valve completely and check
piping installation for leaks.
Valve Assembly
Tie
Rod
Tie Rod Nut
(110-064)
Do not apply pipe sealant
to compression fittings.
Flexible
Hose
(269-2053)
Stop
(S27-340)
Cold
Hot
I.R. Valve with
Tempered Line Not
Shown (S45-2505)
Volume
Control
I.R. Valve with Thermostatic
Mixing Valve (Shown) (S45-2504)
3/8" Tubing from Sprayhead
3/8" Tubing from
Sprayhead
I.R. Valve with
Tempered Line Not
Shown (S45-2505)
Do not apply
pipe sealant to
compression
fittings.