TDB3104, WF3204
Installation
8
1/15/2013
Bradley
• 215-1332 Rev. V; ECN 12-00-004
1
Rough-in Drain and Supplies
A
Rough in supply and drain piping
as required for your installation.
CAUTION! Bowl surface is very smooth. Approximate
weight of bowl is 75 pounds. Handle with Care!
2
Bowl/Pedestal Mounting and Assembly
A
Attach the stainless steel pedestal base
to the pedestal using supplied screws and
finishing washers.
C
Secure pedestal to wall with suitable
fasteners, 1/2" anchors and 1/2" bolts
(supplied by installer).
D
Using two people, carefully lift bowl onto
pedestal.
E
Position the bowl so that the threaded rods
in the bowl mate with the slotted holes in
the pedestal.
F
Using 1/4" wing nuts and washers, secure
the bowl to the pedestal, three places.
Top View
Drain
A location to plug in the 24 VAC Tramsformer is
required. Refer to drawing for Outlet Rough-In.
Position the pedestal at the desired location
and mark the position of the (4) pedestal
wall mounting locations.
B
Front View
Place Hands
Here When
Lifting Bowl
Threaded Rod
(Secured by 1/4"
wing nut and
washer)
Pedestal
(219-039)
Base Assembly, Standard Height
(S17-281)
Base Assembly, TAS (S17-284)
Base Assembly, Juvenile Height
(S17-285)
Shell, Wall Mounted - Trim Piece
(186-1306)
Wall Mounting
Locations
(Typical)
Place Hands
Here When
Lifting Bowl
Drain
#10 - 24 Screw (3)
(160-248)
Finish Washers (3)
(142-002CA)
Before attaching 1/4" wing nuts and washer to
threaded rod, remove red protective caps from
threaded rods. Discard sleeve caps after removal.