Installation
TDB3104, WF3204
Bradley
• 215-1332 Rev. V; ECN 12-00-004
1/15/2013
7
Rough-In Specifications
(mm)
Type A Drain
- Supplies through wall
- Vented through wall
off-drain
Trap for Wall Outlet Only
Type O Drain
- Supplies from above
- Vented through wall
off drain
13" R Top Access
Trap
36" (914) Bowl
1-1/2" NPT Drain
1"
(25)
7/8"
(22)
Hot
Cold
7/8"
(22)
Trap for Wall Outlet Only
4"
(102)
1-1/2" NPT Drain
Through Wall
(Stub Out to Suit
Trap Dimensions)
7-3/8" R. Bottom Access
W
all
1/2" Nominal Copper
Tubing for Cold Supply,
Through Wall
36" Bowl
(914)
1-1/2" NPT Drain
5" R. Bottom Access
1/2" Nominal Copper
Tubing for Hot Supply,
Through Wall
1" (25)
2"
(51)
2"
(51)
Drain P-Trap and supplies by others.
4"
(102)
Clearance Hole
4-3/4"
(121)
*12"
(305)
*17-21"
(432 - 533)
Drain through Wall
Supplies through Wall
1/2" Nominal Copper Tubing
Supplies from Above
4"
(102)
Clearance Hole
4-3/4"
(121)
*17-21"
(432 - 533)
Drain through Wall
*Adjustments to Vertical Dimensions
for Various Rim Heights
Rim Height
Application
Adjustment
34"
35" (WF3203)
Adult Height ADA, TAS Adult Height
None, as shown
32"
TAS Ages 11 thru 14 or 15, Grades
6 thru 8 or 9
Subtract 2"
30"
TAS Ages 4 thru 10 or 11, Grades
Pre-K thru 5 or 6 & Proposed
Juvenile Height ADA
Subtract 4"
4-3/4"
(121)