Installation
Lenox
®
Lockers (includes Cubby & "Z" Lockers)
Bradley •
LK-INSTR-001 Rev. N; ECN 17-13-005
10/19/2017
9
Figure 6
Figure 5
END
FILLER
BLOCKING
(provided by
Installer)
RIVET
(FAST-LF029)
Optional End Filler Installation
5
Fillers are designed to fill gaps between locker runs. They are cut
to size by the installer and attached with 3-4 suitable fasteners
supplied by the installer. The fillers are attached to either an
adjoining locker or blocking (the blocking provides support at the
end of a locker run). If fillers are being attached to a wall, attach
the blocking to the wall first, then secure with suitable fasteners
(blocking and fasteners are supplied by installer). Make sure the
blocking is positioned so that the filler will be flush with the face
with the locker.
Be sure to attach the filler to the proper side of the locker per
your submittal layout.
1 . Cut the end locker filler to size .
2 . Align the filler to the locker top and front and temporarily clamp
in place .
3 . Using the holes in the filler as a template, drill four 9/32" dia .
holes through the locker (refer to Figure 2 on page 5) .
4 . Secure one side of the filler to the locker with the #10-24 male
and #10-24 x 1/2" female sex bolts provided .
5 . Secure the other side of the filler to the blocking (fasteners
provided by installer) .
Number Plate Installation
6
Installation of the number plate is for a standard or “Z"
locker only. Cubby locker does not have a number plate.
1 . Determine the locker number sequence .
2 . Position the number plate in the recess in the locker door
(see Figure 6) .
3 . Hold the plate in place with your finger and, using a pop
rivet gun, install the two rivets into the plate from the front of
the locker .