NOTICE! Make sure the base is square AND level before anchoring to the floor (the base may be square but not
level so be sure to check both). This will ensure proper locker operation.
Figure 1
WALL/FLOOR INTERSECTION
END CAP
LOCKER BASE (FOR
WALL-MOUNTED
LOCKERS)
LOCKER BASE (FOR
ISLAND LOCKERS)
1/4 x 1-3/4" LG .
TAPCON SCREW
(FAST-LF015)
ANGLE
BRACKET
(HW0018)
#10-1/2"
LG . SCREW
(FAST-T349)
ISLAND BASE
END CAP
MENDING PLATE
(HW0048)
Optional Locker Base Installation
1
The base sections are shipped in standard lengths and come with slotted end caps. The length of the base
sections can be easily modified during installation by cutting one end to the desired length. DO NOT cut the
end caps.
1 . Measure and scribe placement lines for the locker base sections .
2 . Position the base sections per submittal layout . The ends of the base sections fit into the slots in the end caps
(see Figure 1) . Square and plumb the sections and end caps using shims as required . If shims are used, place
them under the mounting brackets perpendicular to the bracket .
3 . For longer locker runs, the base sections may need to be connected together . Drill 1/16" pilot holes 1/2" deep
for the #10 x 1/2" screws that fasten the angle bracket and mending plate to the base . Use the mending plate
and #10 x 1/2" screws provided to connect pieces (see Figure 1) .
4 . Using the applicable mounting hardware supplied, anchor the base sections to the floor . Use a 3/16" masonry
drill bit for 1/4" x 1-3/4" Tapcon screws (see inset, Figure 1) .