Express
®
Lavatory System - MG-Series with TouchTime
®
Control
MG-2/TT
Installation
10
4/9/2014
Bradley
• 215-1480 Rev. G; ECN 13-08-025
Installation Instructions
continued . . .
Step 5: Connecting supply
1. Loosen but do not remove the two mounting screws holding the valve bracket to the frame. Slide the
valve bracket up until the larger cutout in the frame’s slot aligns with the screw head (see Figure 5b).
Then lift up to remove the valve bracket from the frame.
2 FOR HOT AND COLD SUPPLY: Attach the stops to the hot and cold water supply piping from the wall.
Connect the flexible hoses to the Navigator Mixing Valve and to the stops (see Figure 5a).
NOTE: The “H” on Navigator Mixing Valve indicates hot water supply inlet.
FOR SINGLE TEMPERED SUPPLY: Attach the stop to the ½" tempered supply line. Connect the stop to
the tempered line adapter with the flexible supply hose (Figure 5c).
3. Assemble the P-trap by connecting the 1½" tubular pipe to the tailpiece and to the 1½" drain pipe stubbed
out of the wall.
4. Install the strainer on the drain plug opening inside the bowl, and push the strainer firmly into place.
Secure the stainer with the screw provided.
Figure 5a
FLEXIBLE SUPPLY
HOSE
NAVIGATOR
THERMOSTATIC
MIXING VALVE
FLEXIBLE
SUPPLY
HOSE
CONNECT TO
HOT WATER
SUPPLY
CONNECT TO
COLD WATER
SUPPLY
Figure 5c
FLEXIBLE
SUPPLY HOSE
(TO SOLENOID
BRACKET)
TO SUPPLY LINE
TEMPERED
LINE ADAPTER
(S39-804)
Hot and
Cold
Supplies
Single
Tempered
Supply
Figure 5b
SLOT IN
FRAME
VALVE BRACKET
MOUNTING SCREW