Step 4: Install bowl assembly
IMPORTANT: See Figure 4 below when installing the bowl assembly. If the fixture has soap option,
refer to the soap installation manual 215-1585 before installing the bowl assembly.
1. With someone to assist you, place the bowl assembly squarely onto the frame being careful not to pinch
tubing between bowl and frame.
2. Attach the front of the bowl assembly to the frame using the two ¼-20 x ½" pan-head
screws and washers provided.
Do not tighten screws at this time.
IMPORTANT: When bolting the bowl assembly to the wall, do not overtighten the bolts.
Overtightening bolts can damage the Terreon
®
material.
3. After the bowl assembly is attached to the frame, install the two
³⁄₈
" bolts and washers
(supplied by the installer) to bolt the bowl to the wall anchors.
Do not overtighten bolts.
4. Tighten the screws installed in procedure #2 above to secure the bowl assembly to the frame.
Do not overtighten.
5. If necessary, adjust sprayhead body to fit closely to wall by adjusting sprayhead mounting bolts. See
Figure 8 on page 14 for sprayhead mounting bolt locations.
Figure 4
³⁄₈
" BOLT
AND WASHER
TERREON
®
END CAP (R)
TERREON
®
END CAP (L)
FRAME
SPRAYHEAD
³⁄₈
" BOLT
AND WASHER
BOWL
¼"-20 x ½"
PAN HEAD
SCREWS AND
WASHERS
(2) PLACES
BACK VIEW