Express
®
Lavatory System - MG-Series with TouchTime
®
Control
Installation
MG-2/TT
Bradley
• 215-1480 Rev. G; ECN 13-08-025
4/9/2014
7
Installation Instructions
continued . . .
Step 2: Rough in wall anchors and electrical outlet
IMPORTANT: Turn OFF electrical power to the outlet when installing the Express
®
Lavatory
System.
1. Install a 110 volt GFI protected electrical outlet per local code at the location shown in Figure 2.
2. Install six
³⁄₈
" wall anchors with a minimum pull-out rating of 1,000 lbs. (supplied by installer) at the
locations marked (ref. location “B” shown in Figure 1, 1a or 1b on pages 5-6).
NOTE: The dimensions for the wall anchors at location "A" are for reference only.
3. On the back of the bowl, measure the distance between the ¾" bowl mounting holes. Divide this
measurement in half. Measure and mark this dimension on the wall to the left of the centerline and to the
right of the centerline. Install two
³⁄₈
" wall anchors with a minimum pull-out rating of 1,000 lbs. (supplied by
installer) at the locations marked (ref. location "A" shown in Figure 1, 1a or 1b on pages 5-6).
NOTE: The anchors will be used to mount the Express
®
MG-2/IR bowl and frame to the wall.
Figure 2
110 VOLT GFCI
ELECTRICAL OUTLET
TRANSFORMER
LOCATION
½" NOMINAL
COPPER TUBING
FOR HOT AND
COLD SUPPLIES OR
TEMPERED SUPPLY.
STUB OUT 2”
1½" NPT DRAIN
STUB OUT 2”