Step 8: Adjust the temperature
1. Check the temperature when approximately 1.0 GPM water flow is reached and adjust if necessary (the
range of the valve is 95°F–125°F (35°C–52°C).
2. Loosen Cap Screw about ¼" (4-6 turns) and lift up cover (do not remove).
3. Using cover, turn cartridge gently until desired water temperature is reached. Do not turn past stops as
this may damage unit. Push cover down and tighten screw.
4. Reinstall panel to frame with the five Torx-head screws provided (see Figure 3 on page 8).
NOTE: Push button activation takes place only when released, (prevents “hold open” activation).
This valve is NOT factory preset. Upon installation, the temperature of this valve must be checked and adjusted
to ensure delivery of a safe water temperature. Water in excess of 110°F (43°C) may cause scalding.