3 of 8
1/29/2018
Bradley
• 215-1833-4 Rev. A: ECN 17-00-021A
Bowl and Pedestal Assembly (Stainless Steel & Terrazzo)
WF2605, WF2608, WF2705, WF2708
P.O. Box 309
•
Menomonee Falls, WI 53052-0309
•
1 800 BRADLEY
•
262 251 6000
•
bradleycorp.com
Length of Tie Pipe Required for Vent Through Washfountain Column
Type
Pipe Length
54" Less Soap Dispenser
21-1/2" (543mm)
36" Less Soap Dispenser
18" (457mm)
54" with Soap Dispenser
30" (762mm)
36" with Soap Dispenser
26-1/2" (673)
54" Less Soap Dispenser with Towel Dispenser
55-1/2" (1410mm)
36" Less Soap Dispenser with Towel Dispenser
52" (1321mm)
54" with Soap Dispenser with Towel Dispenser
48" (1213mm)
36" with Soap Dispenser with Towel Dispenser
44-1/2" (1130mm)
54" with Cube Adapter
32" (813mm)
36" with Cube Adapter
28-1/2" (724mm)
54" with Cube Adapter with Towel Dispenser
50" (1270mm)
36" with Cube Adapter with Towel Dispenser
46-1/2" (1181mm)
54" with Cube Adapter and Soap Dispenser
40" (1016mm)
36" with Cube Adapter and Soap Dispenser
36-1/2" (927mm)
Drain must be connected with 2" schedule 40 welded wrought iron pipe, minimum, to provide lower support
for this installation. Vent or support pipe must be of the same material in 1-1/2". For detailed tie pipe
information, see 215-1834-26.