6 of 10
1/29/2018
Bradley
• 215-1834-32 Rev. A: ECN 17-00-020
TouchTime
®
Activation Modules - Non-Sectional Circular Washfountains
WF2505, WF2508, WF2605, WF2608, WF2705, WF2708, WF2805 & WF2808
P.O. Box 309
•
Menomonee Falls, WI 53052-0309
•
1 800 BRADLEY
•
262 251 6000
•
bradleycorp.com
A
Connect 1/2" dia. tubing
from the sprayhead to
the solenoid assembly.
The male connector
for the valve assembly
will remain tight and
leakproof when tubing is
cut and installed properly.
Follow the procedures
below when installing
tubing to ensure that you
achieve a leakproof seal.
• Using a sharp razor,
cut tubing squarely
and remove any burrs.
DO NOT pinch or
crush end of tubing.
• Loosen nut on fitting.
Moisten end of tube
and push into fitting
until it is firmly seated.
Tighten nut to secure
tube to fitting (make
sure nut is securely
tightened).
• If connector leaks,
reseat tubing
according to above
procedure. If leaking
persists, replace male
connector, or call your
Bradley representative
for assistance.
Flush supply lines before making connections.
2
Connect Valve and Tubing for Non-Sectional TouchTime Control
Other components not shown for clarity.
Connector (269-626)
Valve (S07-095)
Nut (110-216)
Tailpiece (129-055)
Pipe (113-006AL)
Elbow (169-053B)
Reducer (269-851)
Angle Volume Control
Valve (S02-045)
Distance to Finished
Floor (See Table)
Tailpiece Nut
(110-005)
Fiber Washer
(124-001AF)
Optional
TMA
(S01-526)
Stop-Strainer-Check
Valve (S60-003)
1/2" Supply
Manual Mixing Valve
(S01-038)
Distance from 1/2" Supply to Finished Floor
Model
Type A
Type B
Type O
Type H
Standard
Height
9"
(229mm)
6-3/16"
(157mm)
9"
(229mm)
6-3/16"
(157mm)
Juvenile
Height
5-1/4"
(133mm)
3-7/16"
(87mm)
5-1/4"
(133mm)
3-7/16"
(87mm)
Connect 1/2" OD
Supply Tubing from
Sprayhead - See
215-1834-21 for
connection detail.
B
Connect the stop-strainer-check
valves, mixing valve, volume
control valve and solenoid valve
assembly to the supplies as
shown. Use pipe sealant to seal
threads.