4 of 10
1/29/2018
Bradley
• 215-1834-32 Rev. A: ECN 17-00-020
TouchTime
®
Activation Modules - Non-Sectional Circular Washfountains
WF2505, WF2508, WF2605, WF2608, WF2705, WF2708, WF2805 & WF2808
P.O. Box 309
•
Menomonee Falls, WI 53052-0309
•
1 800 BRADLEY
•
262 251 6000
•
bradleycorp.com
Cover
TouchTime
Module
Assembly
Sprayhead
Tie Bar
Supply Tube
Section View of
B/H Unit Assembly
Some optional equipment shown.
1b
Assemble TouchTime
®
– B and H Units (B Shown)
Type "B" Drain
(Supplies from Above)
Supplies 1/2" Nom.
Copper Tubing
Dispenser Cover
Cap Screw
(160-108)
Soap Dispenser
Spacer
(113-155A)
Soap Dispenser Lid
Upper Tie Bar -
Location For Unit with
Soap (159-020)
Upper Tie Bar - Location for Unit
without Soap (159-020)
Parts shown in box
are for unit with
soap dispenser
1-1/2" Vent Pipe
Sprayhead
(S05-054)
Support Tube
(S57-006 36" Bowl)
(S57-006 54" Bowl)
Vented Trap
(111-024)
See Valve Connections
section for valve assembly
1/2" Supply Tube
Support Tube Gasket
(125-011 Terreon/Bradstone/Terrazzo)
(125-008 Stainless Steel)
Type "H" Drain
Hot
Cold
TouchTime Module Assembly
Pushbutton (S83-340-DC)
Piezo Switch (S83-383-DC)
B
Place sprayhead with 1/2" tubing onto
support tube. Run the tubing down
through the support tube and connect to
valve tube connector.
C
Place the TouchTime module assembly
on top of sprayhead. Rotate until module
locks in with tie bar. Run TouchTime button
cables through the support tube down into
the pedestal and connect to the TouchTime
modules, taking care that each sprayhead
section's 1/4" supply tube and TouchTime
module cable are then connected to the
same valve (see details in sections 2 and 3).
A
Install hemmed end (not sharp end)
of support tube with gasket onto bowl.
Connect 1/2" dia. tubing to sprayhead.
• Using a sharp razor, cut tubing squarely
and remove any burrs. DO NOT pinch
or crush end of tubing.
• Loosen nut on fitting. Moisten end of
tube and push into fitting until it is firmly
seated. Tighten nut to secure tube
to fitting (make sure nut is securely
tightened).
• If connector leaks, reseat tubing
according to above procedure. If leaking
persists, replace male connector, or
call your Bradley representative for
assistance.