9 of 10
1/29/2018
Bradley
• 215-1834-32 Rev. A: ECN 17-00-020
TouchTime
®
Activation Modules - Non-Sectional Circular Washfountains
WF2505, WF2508, WF2605, WF2608, WF2705, WF2708, WF2805 & WF2808
P.O. Box 309
•
Menomonee Falls, WI 53052-0309
•
1 800 BRADLEY
•
262 251 6000
•
bradleycorp.com
Check to make sure stop valves are open
before turning on water.
B
Turn on water supply and check for leaks.
Activate each pushbutton/piezo switch to
purge air from the lines.
A
Turn on power to transformer. The solenoid
will buzz when a pushbutton/piezo switch is
activated. If no buzz, check wiring.
C
Gently turn the manual
mixing valve handle
until desired water
temperature is reached.
On units ordered with optional TMA,
temperatures are NOT factory preset.
Upon installation, the temperature of
these valves must be checked and
adjusted to ensure delivery of a safe
water temperature. Water in excess of
110°F (43°C) may cause scalding.
5
Turn on Water and Electricity, Test and Adjust Unit
Adjusting the TouchTime Module
4
The TouchTime module is set at the factory with the selector
switch in position 5. This provides a 15 second time out period.
To adjust the TouchTime module to a
different time out period, turn the selector
switch to the desired time out setting (4
through 9 for no flush, A through F for 24
hours flush) as indicated on the module
label.
A
The 24 hour flush function will activate water flow for a period
of 60 seconds any time there has been no activation within the
past 24 hours. This function is used to help clear stagnant water
from the plumbing system and can provide some measure of
prevention against the formation of bacteria in supply pipes.
Pushbutton
Connectors (Can use
either one or both)
LED Indicator
Selector Switch
Power
Connection
H
C
Manual Mixing Valve