P.O. Box 309

Menomonee Falls, WI 53052 USA

800 BRADLEY (800 272 3539)

+1 262 251 6000

bradleycorp.com

WF2500 Series Terreon Classic
WF2600 Series Terrazzo
WF2700 Series Stainless Steel
WF2800 Series Bradstone
WF3200 Series Terreon Deep Bowl
TDB3100 Series Terreon Deep Bowl

WF3203

215-1833-10 Rev. A; ECN 17-00-006B
© 2017 Bradley
Page 1 of 2 

11/21/2017

WF2605

WARNING

Make sure that all water supply lines have been flushed and then completely turned off before beginning 
isntallation. Debris in the supply lines can cause valves to malfunction.

Turn OFF electrical supply to the unit before installation.

NOTICE

Main water supply to the unit should be "ON" at all times.

IMPORTANT

Read this installation manual completely to ensure proper installation, then file it with the owner or 
maintenance department. Compliance and conformity to drain requirements and other local codes and 
ordinances is the responsibility  of the installer.

Separate parts from packaging and make sure all parts are accounted for before discarding any packaging 
material. If any parts are missing, do not begin installation until you obtain the missing parts.

Product warranties and parts information may also be found under ”Products” on our web site at bradleycorp.com.

Содержание Bradstone WF2800 Series

Страница 1: ...an cause valves to malfunction Turn OFF electrical supply to the unit before installation NOTICE Main water supply to the unit should be ON at all times IMPORTANT Read this installation manual completely to ensure proper installation then file it with the owner or maintenance department Compliance and conformity to drain requirements and other local codes and ordinances is the responsibility of th...

Страница 2: ... conditions is essential Always start with the simplest solution and work your way toward the more complicated Routine cleaning Daily or as often as needed use a solution of warm water and soap detergent or ammonia Apply the cleaning solution per the manufacturer s instructions and always use a soft cloth or sponge to avoid damaging the finish Stubborn Stains To remove stains from stainless steel ...

Страница 3: ...ons before turning on the water NOTICE If the bowl is not completely dry before applying the polyurethane the polyurethane will not adhere to the surface NOTICE Make sure the surface is complete covered with polyurethane to prevent water from penetrating the surface and damaging the terrazzo Repair Kits Terrazzo repair kits are available Contact your Bradley representative or distributor for part ...

Страница 4: ...on instructions Standard 2 P trap vented trap supplied by Bradley when required 2 drain lines and fittings see activation instructions 1 1 2 vent pipe on types vented through washfountain column Pipe sealant and plumber s putty Before installation of bowl and pedestal assemblies review all included instructions Some options may require additional steps during the bowl and pedestal installation pro...

Страница 5: ...ss 54 19 28 37 3 8 45 7 8 54 1 4 32 36 54 Terrazzo 36 19 29 1 4 35 5 8 44 1 8 52 1 2 21 25 36 Stainless 36 19 28 33 7 8 42 3 8 50 3 4 21 25 36 Juvenile height terrazzo only Subtract 4 from dimensions A through E for juvenile height Approximate Dimensions in Millimeters Material Size A B C D E F G H Terrazzo 1372mm 483 743 994 1210 1422 813 914 1372 Stainless 1372mm 483 711 949 1165 1378 813 914 13...

Страница 6: ...5 1 2 1410mm 36 Less Soap Dispenser with Towel Dispenser 52 1321mm 54 with Soap Dispenser with Towel Dispenser 48 1213mm 36 with Soap Dispenser with Towel Dispenser 44 1 2 1130mm 54 with Cube Adapter 32 813mm 36 with Cube Adapter 28 1 2 724mm 54 with Cube Adapter with Towel Dispenser 50 1270mm 36 with Cube Adapter with Towel Dispenser 46 1 2 1181mm 54 with Cube Adapter and Soap Dispenser 40 1016mm...

Страница 7: ...Nom Copper Tube on These Centers To Pass Thru Washfountain 7 8 22 7 8 22 Hot 1 1 2 NPT Vent to Ceiling 1 1 4 32 4 102 2 NPT Drain Stub Up 3 76 Above Floor 54 1372 Bowl Cold UPC and IPC restricts the vertical distance from the fixture outlet to the trap weir to not more than 24 Check state and local codes for variances 36 914 Bowl 36 914 Bowl Rough In Notes 1 All pipes and fittings not furnished by...

Страница 8: ...Above Must Reduce to 1 2 Nom Copper Tube on These Centers to Pass Thru Washfountain 7 8 22 7 8 22 Cold Hot 1 1 4 32 4 102 2 NPT Drain Stub Up 3 76 Above Floor 54 1372 Bowl UPC and IPC restricts the vertical distance from the fixture outlet to the trap weir to not more than 24 Check state and local codes for variances 36 914 Bowl Some optional equipment shown 54 1372 Bowl Rough In Notes 1 All pipes...

Страница 9: ...y installer Trap Dimensions mm Bowl Material Size Dim Standard Height Juvenile Height Terrazzo 36 B 18 5 8 473 14 5 8 371 Terrazzo 54 B 18 5 8 473 14 5 8 371 Stainless Steel 36 B 17 3 8 441 N A Stainless Steel 54 B 17 432 N A Stainless steel is not available in juvenile height Types B and H 4 102 Types A and O Fixture Centerline B Vent or Tie Pipe Supplied by Installer B Types A and O With Tie Pip...

Страница 10: ...age bolts and nuts provided B Attach the pedestal frame members with the 5 16 stove bolts and nuts provided C Add the foot levers and operating cross to the pedestal assembly D Press the foot rail into place with a rolling motion The joint of the foot rain should be placed in the clevis of one of the foot valves 2b Assembling the Pedestal without Foot Control A Assemble the leg and scuff base pane...

Страница 11: ...way into the drain to ensure correct alignment E Anchor the pedestal assembly to the floor with suitable anchors fasteners supplied by installer Top View of Pedestal Assembly CAUTION Bowl surface is smooth Use suitable lifting equipment to position bowl and pedestal assembly Handle with care A Position the pedestal as shown in pedestal assembly drawing B Place the bowl on the pedestal using suitab...

Страница 12: ...d Circular Shown S34 038 Semi Circular Similar S34 037 Connector 1 4 NPT x 1 4 Tube 169 974 1 4 Supply Tubing 4 Required for Circular 2 Required for Semi Circular Parts List Item Part No Description Circular Semi Circular Qty 1 115 080 Sectional Sprayhead Plated Circular 1 1 115 079 Sectional Sprayhead Plated Semi Circular 1 2 159 115 Bottom Plate 1 1 3 124 032 Gasket 1 1 4 160 138 Screw 10 24 x 1...

Страница 13: ... separate item 1 2 3 4 5 9 6 8 7 10 Parts List Item Part No Description Sprayhead Assembly Repair Kit S45 051 Qty 1 125 001DE Neoprene Washer Top 1 1 2 139 031 Sprayhead Manifold 1 3 124 001AL Washer 3 4 4 160 211 Carriage Bolt 3 4 5 115 061 Sprayhead Top 1 6 116 008 Sprayhead Bottom 1 7 124 001AT Washer 3 4 8 161 025 Nut 3 4 9 124 020C Sprayhead Grommet Circle 1 9 120 020D Sprayhead Grommet Semi ...

Страница 14: ...rayhead Strainer portion of the stop strainer check valve is plugged Remove and clean the strainer screen from the stop strainer check valve The non sectional sprayhead includes a perforated neoprene spray ring grommet that is self cleaning The water pressure flexes the spray holes which slows accumulation of foreign matter and tends to break loose any such deposits that may have accumulated Spray...

Страница 15: ...ry during regular maintenance and service Pre Installation Information TouchTime TouchTime pushbutton piezo switch activates a flow of water Sprayhead is controlled by a solenoid valve allowing user to activate a flow of tempered water from sprayhead with a pushbutton for 15 seconds Valve uses less than half the maximum amount of hot water allowed by the ANSI ASHRAE ES 90A 1980 standard Activation...

Страница 16: ...port Tube S57 006 36 Bowl S57 006 54 Bowl 1 2 Supply Tube Lower Tie Bar 159 009 Lower Longest Tie Rod 176 008 36 Bowl 176 008A 54 Bowl Tie Rod Hex Nut 110 064 Set Screw 160 208 See Valve Connections section for valve assembly Hot Cold Support Tube Gasket 125 011 Terreon Bradstone Terrazzo 125 008 Stainless Steel B Place sprayhead with 1 2 tubing onto support tube Run the tubing down through the su...

Страница 17: ...semble TouchTime A and O Units O Shown cont D Place the TouchTime module assembly on top of sprayhead Rotate until module locks in with tie bar Run TouchTime button cables through the support tube down into the pedestal and connect to the TouchTime modules taking care that each sprayhead section s 1 2 supply tube and TouchTime module cable are connected to the same valve see details in Steps 2 and...

Страница 18: ...errazzo 125 008 Stainless Steel Type H Drain Hot Cold TouchTime Module Assembly Pushbutton S83 340 DC Piezo Switch S83 383 DC B Place sprayhead with 1 2 tubing onto support tube Run the tubing down through the support tube and connect to valve tube connector C Place the TouchTime module assembly on top of sprayhead Rotate until module locks in with tie bar Run TouchTime button cables through the s...

Страница 19: ...its without soap E For units with soap option install the spacer soap dispenser and cover in position on top of air module Slide tie bar over 1 1 2 vent pipe 1 2 below top of soap dispenser lid and secure with set screws Slide the dispenser cover over 1 1 2 vent pipe and secure with 2 screws included with tie bar F Slide tie bar over 1 1 2 vent pipe 1 2 below top of air module cover and secure wit...

Страница 20: ...bing according to above procedure If leaking persists replace male connector or call your Bradley representative for assistance Flush supply lines before making connections 2 Connect Valve and Tubing for Non Sectional TouchTime Control Other components not shown for clarity Connector 269 626 Valve S07 095 Nut 110 216 Tailpiece 129 055 Pipe 113 006AL Elbow 169 053B Reducer 269 851 Angle Volume Cont...

Страница 21: ... indicated in table on previous page 2 Connect Valve and Tubing for Non Sectional TouchTime Control Cont C For overhead supply install 1 2 nominal copper supply tubing by passing lines through holes in the dispenser cover and then down through the support tube F When tubing and wiring connections see electrical connections section are complete angle volume control valve is to be used as volume con...

Страница 22: ...d will result in damage to the electronics Mechanical pushbutton shown piezo switch similar TouchTime Piezo Non Sectional Connection Box S83 412 TouchTime Module S83 360 Mechanical TouchTime Pushbutton S83 368 Piezo Switch Button S83 369 Plug In Adapter 261 147A Activation of the push button takes place only when it is released thereby preventing hold open activation Connect splitter connector to ...

Страница 23: ...st be checked and adjusted to ensure delivery of a safe water temperature Water in excess of 110 F 43 C may cause scalding 5 Turn on Water and Electricity Test and Adjust Unit Adjusting the TouchTime Module 4 The TouchTime module is set at the factory with the selector switch in position 5 This provides a 15 second time out period To adjust the TouchTime module to a different time out period turn ...

Страница 24: ...vidual operating station fails to turn on A failed cartridge for the valve or loose electrical connection to the terminal Test the station to determine the cause 1 Disconnect the wires from the cartridge of an adjacent valve Disconnect the wires from the problem valve and reconnect to the adjacent valve 2 Turn on electrical and water supplies to the unit Activate the pushbutton piezo switch on the...

Отзывы: