Appliance details
RTG 199 ME – 6 720 811 615 (2015/04)
7
3
Appliance details
3.1
Features
Parts
• Key Pad interface control.
• High power pre-mix compact burner with low NOx emissions.
• Modulating Gas Valve with constant gas:air ratio control.
• Modulating water valve for improved comfort and temperature
control.
High quality materials for long working life
• Copper heat exchanger.
• High efficiency Ceramat Burner.
• Compact space saver: mounts on a wall with a supplied bracket.
Features
• Easily removable one-piece cover.
• On/Off and Temperature control switches.
• Reset button.
• Program button (Selectable temperature default).
• Failure codes for easy diagnostics and repair.
• Real-time diagnostics for troubleshooting/informational purposes.
• Built in freeze prevention.
Note: The freeze prevention kit is designed to provide protection for the
water heater down to approximately 5°F for short term conditions only.
It will not protect the appliance in areas where the temperature is
routinely expected to be below freezing.
- The freeze prevention kit will not protect plumbing outside the
appliance from freezing. Precautions should be taken.
3.2
Specifications (Technical data)
Approved in US/Canada
Bradford White is constantly improving its products,
therefore specifications are subject to change without
prior notice.
Technical characteristics
Units
RTG 199 ME
Capacity
Maximum flow rate at a 45 °F
(25 °C) rise
GPM (l/min)
7.3 (27.7)
Maximum flow rate at a 55 °F
(30.6 °C) rise
GPM (l/min)
6.0 (22.7)
Maximum flow rate at a 75 °F
(41.7 °C) rise
GPM (l/min)
4.4 (16.6)
Maximum flow rate at a 90 °F
(50 °C) rise
GPM (l/min)
3.7 (13.9)
Maximum output
BTU/hr (kW)
160,500 (47)
Maximum input
BTU/hr (kW)
199,000 (58.3)
Thermal efficiency (Efficiency
in %)
%
> 83%
Minimum Input
BTU/hr (kW)
19,900 (5.8)
Temperature Control
Selection range
°F ( °C)
100 - 140 (38 - 60)
Default temperature
°F ( °C)
122 (50)
Stability
°F ( °C)
2 (
1)
Gas Requirement
Gas connection
inches
¾ "
Peak load inlet gas pressure
1)
Propane
water column
8” - 13”
Natural Gas
water column
3.5” - 10.5”
Water
Hot water connection
inches
¾ "
Cold water connection
inches
¾ "
Minimum water flow
2)
GPM (l/min)
0.5 (1.9)
Minimum recommended
water pressure
PSI (bar)
30 (2.07)
Minimum well pressure
PSI
40
Water valve material
Polymer (PPS)
(Polypropylene
Sulfide)
Connections:
Bottom of heater
Combustion
CO level
ppm
250 (measured)
CO
2
level (set from factory)
%
Dimensions
Depth
inches (mm)
11 ¼ (286)
Width
inches (mm)
17
7
/
8
(452)
Height
inches (mm)
30½ (775)
Weight
pounds (kg)
67 (30.5)
Gas types
Natural Gas
Table 3
Содержание RTG 199 MEN
Страница 49: ...Functional scheme RTG 199 ME 6 720 811 615 2015 04 49 12 Functional scheme Fig 69 Functional scheme...
Страница 55: ...RTG 199 ME 6 720 811 615 2015 04 55 Notes...
Страница 56: ......