Installation instructions
RTG 199 ME – 6 720 811 615 (2015/04)
19
Fig. 19
[1]
Appliance
[2]
Condensate drain
[3]
Elbow
[4]
Hose clamp
[5]
Hanger strap
[6]
Horizontal run ¼ " rise/ft
[7]
May be insulated if necessary
[8]
Chimney
[9]
Rain cap
[10] Storm collar
[11] Flashing
[12] Silicone seal
4.3.4
Vent connections
Attaching the exhaust and air inlet connection adaptors to the top of
the heater
▶ Attach the flue gas exhaust accessory to the top of the unit fig. 20
(position 1) using the 4 screws and gasket provided, and fully insert
vent pipe into the accessory.
▶ If using 4" venting, a 3" to 4" increaser should be installed directly
after this accessory.
Fig. 20 Exhaust connection
▶ Attach the combustion air inlet accessory to the top of the unit fig. 21
(position 2) using the 3 screws and gasket provided, and install 3" air
intake pipe over the accessory.
Fig. 21 Inlet connection
4.3.5
Connecting the external condensate water drain
Note: Adhesive backing needs to be removed prior to
installation.