Installation instructions
RTG 199 ME – 6 720 811 615 (2015/04)
14
Calculation example for 3" venting:
Exhaust
Combustion air
Calculation example for 4" venting:
Exhaust
Combustion air
System used
Concentric
Number of 90° elbows needed:
1
Number of 45° elbows needed:
2
Table 11
Calculation of example
Max. length
28.5’
90° elbow reduction
- 5’
sub-total =
23.5’
45° elbow reduction
- 5’
Total =
18.5’
Table 12
For this example, the maximum allowable exhaust pipe
length is
18.5 feet
.
System used
Concentric
Number of 90° elbows needed:
2
Number of 45° elbows needed:
1
Table 13
Calculation of example
Max. length
28.5’
90° elbow reduction
- 10’
sub-total =
18.5’
45° elbow reduction
- 2.5’
Total =
16’
Table 14
For this example, the maximum allowable combustion
air pipe length is
16 feet
.
System used
Twin pipe
Number of 90° elbows needed:
2
Number of 45° elbows needed:
2
Table 15
Calculation of example
Max. length
61.25’
90° elbow reduction
- 10’
sub-total =
51.25’
45° elbow reduction
- 5’
Total =
46.25’
Table 16
For this example, the maximum allowable exhaust pipe
length is
46.25 feet
.
System used
Twin pipe
Number of 90° elbows needed:
1
Number of 45° elbows needed:
2
Table 17
Calculation of example
Max. length
61.25’
90° elbow reduction
- 5’
sub-total =
56.25’
45° elbow reduction
- 5’
Total =
51.25’
Table 18
For this example, the maximum allowable combustion
air pipe length is
51.25 feet
.