Appliance details
RTG 199 HE – 6 720 811 617 (2016/01)
8
3.3.1
The box includes
• Tankless water heater
• Bracket for wall hanging the heater
• Exhaust vent adaptor (with 4 screws and gasket provided)
• Combustion air inlet adaptor (with 3 screws and gasket provided)
• Installation manual
• Energy Guide label
The RTG 199 H is not approved or designed for:
•
Manufactured (mobile) homes, boats or any mobile installation.
(Modular homes are acceptable for installation).
•
Use above 8000 ft A.S.L. altitude (see page 21).
•
Outdoor installation without installation of Outdoor kit.
•
Applications where inlet water temperature is higher than 140°F
(60°C). A 3-way valve or mixing valve must be installed before
the appliance if inlet water temperature exceeds this limit.
3.3.2
Remove front cover
▶ Loosen the two Phillips head screws located on bottom rear of cover.
Fig. 3
Loosen the two screws
▶ Lift front cover panel upward and remove.
Fig. 4
Remove the front cover
3.3.3
Remove combustion cover (service only)
▶ Open the four clips and remove the combustion cover.
Fig. 5
Remove the combustion cover
3.4
General rules to follow for safe operation
•
1.
You must follow these instructions when you install your heater. In
the United States: The installation must conform with local codes or,
in the absence of local codes, the National Fuel Gas Code ANSI
Z223.1/NFPA 54.
In Canada: The Installation must conform with CSA B149.(1,2)
INSTALLATION CODES and /or local installation codes.
6720608917-03.1AL