Required direct vent terminal clearances (twin pipe / concentric penetration) for PVC, CPVC, ABS, and PP.
Fig. 10
[*]
For clearances not specified in ANSI Z223.1 / NFPA 54 or CSA-B149.1, one of the following shall be indicated:
a) A minimum clearance value determined by testing in accordance with section 2.20, or;
b) A reference to the following footnote:
“Clearance in accordance with local installation codes and the requirements of the gas supplier.”
Canadian installations
1)
1) In accordance with the current CSA B149.1 Natural Gas and Propane Installation Code.
U.S. installations
2)
2) In accordance with the current ANSI Z223.1 / NFPA 54 National Fuel Gas Code.
A
Clearance above grade, veranda, porch, deck or balcony
12 in.
12 in.
B
Clearance to window or door that may be opened
36 in.
12 in.
C
Clearance to permanently closed window
*
*
D
Vertical clearance to ventilated soffit located above the vent
termination within a horizontal distance of 2 feet (61cm) from
the center line of the termination
*
*
E
Clearance to unventilated soffit
*
*
F
Clearance to outside corner
*
*
G
Clearance to inside corner
*
*
H
Clearance to each side of center line extended above meter/
regulator assembly
36 in. within a height 15 feet above
meter/ regulator assembly
*
I
Clearance to service regulator vent outlet
36 in.
*
J
Clearance to non-mechanical air supply inlet to building or the
combustion air inlet to any other application
36 in.
12 in.
K
Clearance to mechanical air supply inlet
72 in.
36 in. above if within 10 feet
horizontally
L
Clearance above paved sidewalk or paved driveway located on
public property
84 in.
3)
3) A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves both dwellings.
*
M
Clearance under veranda, porch deck or balcony
12 in.
4)
4) Permitted only if veranda, porch, deck or balcony is fully open on a minimum of two sides beneath the floor.
*
Table 24