WARNING
For protection against excessive temperatures and pressure, install
temperature and pressure protective equipment required by local codes,
but not less than a combination temperature and pressure relief valve
certified by a nationally recognized testing laboratory that maintains
periodic inspection of production of listed equipment or materials as
meeting the requirements of the Standard for
Relief Valves and Automatic
Gas Shutoff Devices for Hot Water Supply Systems, ANSI Z21.22 or the
Standard CAN1-4.4. Temperature and Pressure
and the Standard
CAN1-
4.4, Temperature, Pressure, Temperature and Pressure Relief Valves and
Vacuum Relief Valves
. The combination temperature and pressure relief
valve shall be marked with a maximum set pressure not to exceed the
maximum working pressure of the water heater. The combination
temperature and pressure relief valve shall also have an hourly rated
temperature steam BTU discharge capacity not less than the hourly rating
of the water heater.
Install the combination temperature and pressure relief valve into the
opening provided and marked for this purpose on the water heater.
Note: Some models may already be equipped or supplied with a
combination temperature and pressure relief valve. Verify that the
combination temperature and pressure relief valve complies with local
codes. If the combination temperature and pressure relief valve does not
comply with local codes, replace it with one that does. Follow the
installation instructions above on this page.
Install a discharge line so that water discharged from the combination
temperature and pressure relief valve will exit within six (6) inches
(15.2
cm)
above, or any distance below the structural floor and cannot contact
any live electrical part. The discharge line is to be installed to allow for
complete drainage of both the combination temperature and pressure
relief valve and the discharge line. The discharge opening must not be
subjected to blockage or freezing.
DO NOT
thread, plug or cap the
discharge line. It is recommended that a minimum clearance of four (4)
inches
(10.2 cm)
be provided on the side of the water heater for servicing
and maintenance of the combination temperature and pressure relief
valve.
Do not place a valve between the combination temperature and pressure
relief valve and the tank.
14
Installation (Water Connections) continued-
This water heater can deliver scalding temperature water at any faucet in the
system. Be careful whenever using hot water to avoid scalding injury.
Certain appliances such as dishwashers and automatic clothes washers may
require increased temperature water. By setting the thermostat on this water
heater to obtain the increased temperature water required by these
appliances, the potential for scald injury increases. To protect against injury,
an anti-scald tempering valve should be installed in the water system. This
valve will reduce point of discharge temperature by mixing cold and hot water
in branch supply lines. Such valves are available from the manufacturer of
this water heater or a local
plumbing supplier. Please consult with a plumbing
professional.
WARNING
Hydrogen gas can be produced in an operating water heater that has
not had water drawn from the tank for a long period of time (generally
two weeks or more). Hydrogen gas is extremely flammable. To
prevent the possibility of injury under these conditions, we
recommend the hot water faucet to be open for several minutes at the
kitchen sink before you use any electrical appliance which is
connected to the hot water system. If hydrogen is present, there will
be an unusual sound such as air escaping through the pipes as hot
water begins to flow. Do not smoke or have open flame near the
faucet at the time it is open.