Страница 1: ...y phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation a...

Страница 2: ...as Installation Code Latest Edition or CAN CGA B149 2 Propane Installation Code Latest Edition The following terms are used throughout this manual to bring attention to the presence of hazards at vari...

Страница 3: ...ions in the proper order can cause personal injury or death Read and understand all instructions including all those provided with the appliance before installing starting up operating maintaining or...

Страница 4: ...is water heater if the input rate exceeds the rate shown on the water heater rating plate This water heater contains very hot water under high pressure Do not unscrew any pipe fittings nor attempt to...

Страница 5: ...as supplier from a telephone in another building Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department DO NOT OPERATE THE APPLIANCE UNTIL THE LEAKAGE IS...

Страница 6: ...Maximum Temp Setting residential 120 F 49 C Minimum Temperature Setting 96 F 36 C 98 F 37 C Weight 46 lb 21 kg 55 lb 25 kg Energy Factor 0 82 0 82 0 82 N A Thermal Efficiency 83 0 Noise level inside...

Страница 7: ...Hot Water Outlet from wall 3 7 8 96 4 1 2 115 F Hot Water Outlet from center 4 3 8 110 2 3 8 61 G Cold Water Inlet from wall 2 5 8 75 3 7 8 99 H Cold Water Inlet from center 1 1 8 27 2 52 I Gas Conne...

Страница 8: ...owing Pressure Drop v Water Flow Rate Figure 2 Graph Showing Water Flow Rate v Temperature Rise TG 237E N X TG 237E N X A TG 237E N X TG 237E N X A TG 199E N X TG 180E N X TG 150E N X TG 150E N X TG 1...

Страница 9: ...Y GAS APPLIANCE IF YOU ARE NOT CERTAIN OF THE FOLLOWING Liquefied petroleum gases propane gas and natural gas have an odorant added by the gas supplier that aids in detection of the gas Most people re...

Страница 10: ...ased room temperature Excessive ambient temperatures surrounding the water heater may shorten the life of the controls WARNING Residential use water heaters are suitable for potable water heating only...

Страница 11: ...enter screw may be first installed in the wall for hanging the water heater on the wall Two more screws are then added on the ends of the bracket to secure the water heater Wall anchors should be used...

Страница 12: ...es of qualified licensed professionals for the installation of hard wired carbon monoxide detectors a In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl s...

Страница 13: ...rances to combustibles whether the closet door is combustible or non combustible FIXED CLOSED OPERABLE FIXED CLOSED OPERABLE B B B A J B I M C F B B E D L G A H K VENT TERMINAL AIR SUPPLY INLET AREA W...

Страница 14: ...mbly I Clearance to service regulator vent outlet 36 inches 91 cm J Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 36 inches 91 cm 12 inche...

Страница 15: ...a dryer vent Avoid termination locations near commercial cooking exhausts 2 36 12 INSIDE CORNER 0 30 m to an inside 50 mm between terminals at same level 0 91 m to ventilated or unventilated soffit or...

Страница 16: ...sary to modify the dip switch settings according to Table 5 Table 5 Dip Switch Settings for High Altitude Installations 0 2000 ft 0 610 m 2001 5200 ft 610 1585 m 5201 7700 ft 1585 2347 m 7701 10200 ft...

Страница 17: ...evels 6 5 to 8 5 Up to 500 ppm Up to 11 7 grains Up to 0 2 ppm Up to 250 ppm Up to 1 0 ppm Up to 0 3 ppm Up to 0 05 ppm Up to 5 ppm Note 1 ppm 1 mg L NOTICE If the EverHot water heater is operated und...

Страница 18: ...inlet filter The inlet strainer prevents debris from damaging the flow sensor or clogging the coil It may need to be cleaned periodically and should be cleaned after the initial operation DO NOT opera...

Страница 19: ...XIMATE TIME TEMPERATURE RELATIONSHIPS IN SCALDS 120 F 49 C More than 5 minutes 125 F 52 C 1 to 2 minutes 130 F 54 C About 30 seconds 135 F 57 C About 10 seconds 140 F 60 C Less than 5 seconds 145 F 63...

Страница 20: ...20 Figure 6 Recommended Piping for a Basic Installation...

Страница 21: ...21 Figure 7 Recommended Piping for a Circulation Systems...

Страница 22: ...and windstorms occur The electrical connections for the two solenoids must be tied to the 120 volt main power supply black and white wires When the electrical power to the water heater fails the sole...

Страница 23: ...l the pressure relief valve into a tee connection from the hot water outlet of the water heater Note Some models may already be equipped or supplied with an installed pressure relief valve Verify that...

Страница 24: ...water heaters will not be covered under warranty for water heating space heating applications 2 The temperature setting of the water heater thermostat must not exceed 160 F 3 In combination space hea...

Страница 25: ...25 Figure 9 Recommended Piping for Combination Water and Space Heating Applications...

Страница 26: ...uld result in fire or explosion If overpressure has occurred such as through improper testing of gas lines or emergency malfunction of the supply system the gas valve must be checked for safe operatio...

Страница 27: ...Use soap and water solution or other material acceptable for the purpose of locating gas leaks WARNING DO NOT use matches candles flame or other sources of ignition for this purpose Table 8 Maximum Ca...

Страница 28: ...in w c Low Fire L P Gas 3 2 5 0 in w c High Fire 0 9 in w c Low Fire High fire manifold pressures vary depending on the water heater s model 6 Turn off the hot water faucets Disconnect the electrical...

Страница 29: ...r should be connected to a GFI outlet and wired on a separate circuit and breaker A strain relief will be required for the line cord Do not plug the line cord into a receptacle that can have the power...

Страница 30: ...DC40V DC5V A B C SG SWITCHING POWERSUPPLY THERMISTOR CIRCUIT B SG RELAY 1 A WATERFLOW SENSOR CIRCUIT WATERFLOW CONTROLDEVICE CIRCUIT A SG A SG SG A QS SG FR FLAME DETECTING CIRCUIT FLAMEROD GND SG A R...

Страница 31: ...31 Figure 11 Wiring Diagram for TG 150E N X TG 180E N X and TG 199E N X Models...

Страница 32: ...32 Figure 12 Wiring Diagram for TG 237E N X and TG 237E N X A Models...

Страница 33: ...2 104 106 108 110 115 120 125 130 135 140 150 160 185 Temp C 37 38 39 40 41 42 43 46 49 52 54 57 60 66 71 85 Re setting the Maximum Temperature For all models except TG 237E N X TG 237E N X A These un...

Страница 34: ...nd display the setpoint of the remote control in use Both the remote controls and the main control will display diagnostic codes in the event the water heater needs service NOTICE No more than four te...

Страница 35: ...rance hole for the cable using a 6 4 mm drill bit 3 Run the cable from the control to the water heater or another control which ever is closer or more convenient 4 Remove the face plate from the contr...

Страница 36: ...s Check the operation of the power failure protection system drain solenoids 3 Explain the proper operation of the new Bradford White EverHot water heater to the end user WARNING Do not attempt to co...

Страница 37: ...ire Color Voltage Resistance Connector No Pin Nos Red Blue 11 13 VDC 22 28 ohms F7 9 10 Grey Brown 4 6 VDC n a F7 5 7 Grey Yellow n a n a F7 5 8 Note The grey wire listed above turns to black at F con...

Страница 38: ...F 11 4 14k 140 F 2 2 2 7k 86 F 6 4 7 8k 221 F 0 6 0 8k 113 3 6 4 5k Table 18 Outgoing Water Thermistor Wire Color Voltage Resistance Connector No Pin Nos White White n a See example above F5 3 4 Tabl...

Страница 39: ...hms through each of these heaters The heater located on the heat exchanger piping should have a resistance reading of 156 180 ohms and the one located in the water flow sensor valve should have a resi...

Страница 40: ...ractor or qualified service professional 1 Flooding to or above the level of the burner or controls 2 External firing 3 Damage 4 Firing without water 5 Sooting Never operate the water heater without f...

Страница 41: ...ll a qualified service technician to inspect the water heater and to replace any part of the control system and any gas control which has been under water OPERATION INSTRUCTIONS 1 STOP Read the safety...

Страница 42: ...A licensed plumbing professional or local plumbing authority should be consulted CAUTION This water heater when set at a lower temperature setting is not capable of producing hot water of sufficient t...

Страница 43: ...ng with the most recent code 7 Press and hold the H button for 2 seconds and without releasing press the Priority button to display the water flow through the water heater with hot water in use GPM Di...

Страница 44: ...your elbow before placing a child in the bath or shower Do not leave a child or an infirm person in the bath unsupervised The following chart details the relationship of water temperature and time wi...

Страница 45: ...nsure all burners are properly seated Remove burner plate and inspect burner surface for condensation or debris 12 Flame Failure Check that the gas is turned on at the water heater and gas meter Check...

Страница 46: ...SV2 and SV3 Solenoid Valve Circuit Fault Check wiring harness to all solenoids for damage and or loose connections Measure resistance of each solenoid valve coil 72 Flame Sensing Device Fault Ensure f...

Страница 47: ...ame Appearance 3 Check the front vent outlet for blockage and clean if necessary Keep shrubs and vegetation clear of the vent terminal 4 All electric motors are permanently lubricated and do not need...

Страница 48: ...mineral deposits Use the following procedure and Figure 20 to flush the heat exchanger and remove the mineral scale 1 Disconnect power to the water heater 2 Close the shut off valves in the cold wate...

Страница 49: ...neral Scale Flushing Rinnai Water Heater Gas Supply V1 V3 V2 V4 H1 H2 H3 Circulating Pump 5 gallon pail of virgin food grade white vinegar or virgin food grade citric acid Cold Water Line Hot Water Li...

Страница 50: ...the water heater To remedy this situation either increase the total water flow from the tap or using the control decrease the setpoint temperature of the water heater to the temperature desired at th...

Страница 51: ...51 SECTION IX PARTS LIST TG 150E TG 180E and TG 199E Models...

Страница 52: ...1 004 Connection Reinforcement Panel 1 1 1 1 1 1 005 Heat Protection Plate 1 1 1 1 1 1 006 Front Panel 1 1 1 1 1 1 007 Front Panel Packing 1 1 1 1 1 1 008 Main Body Packing Side 2 2 2 2 2 2 016 Rubbe...

Страница 53: ...53...

Страница 54: ...1 132 Combustion Chamber Bracket 1 1 1 1 1 1 135 Air Inlet Box All Assembly 1 1 1 1 1 1 137 Connecting Joint 1 1 1 1 1 1 138 Joint Fixing Bracket 1 1 1 1 1 1 143 Heat Exchanger Assembly 1 1 143 Heat...

Страница 55: ...55...

Страница 56: ...t 1 1 1 1 1 1 410 Plug Band small 1 1 1 1 1 1 411 Drain Valve 1 1 1 1 1 1 412 Filter Plug Assembly 1 1 1 1 1 1 413 Cover 1 1 1 1 1 1 700 Electric Unit Assembly 1 1 700 Electric Unit Assembly 1 1 1 1 7...

Страница 57: ...57...

Страница 58: ...Frost Heater 120V 1 1 1 1 1 1 715 Valve Heater 120V Assembly 1 1 1 1 1 1 721 Fuse Harness FF 1 1 1 1 1 1 722 Power Harness 1 1 1 1 1 1 723 Magnet Valve Harness 1 1 1 1 1 1 724 Sensor Harness 1 1 724 S...

Страница 59: ...59 TG 237E Models...

Страница 60: ...2 2 2 010 Front Panel Packing Top 2 2 2 2 011 Front Panel Packing Side 2 2 2 2 012 Connection Reinforcement Panel 1 1 1 1 014 Seal Packing 1 1 1 1 017 Rubber Bushing 1 1 1 1 018 Reinforcement Plate 1...

Страница 61: ...61...

Страница 62: ...125 Heat Exchanger Complete Assembly 1 1 125 Heat Exchanger Complete Assembly 1 1 150 Blower Motor 1 1 1 1 151 Fan Casing Assembly 1 1 1 1 153 Fan Connecting Bracket 1 1 1 1 154 Fan Connecting Packing...

Страница 63: ...63...

Страница 64: ...ssembly 1 1 1 1 408 Stop Bracket 2 2 2 2 409 Water Flow Servo Cover 1 1 1 1 410 Hot Water Outlet 1 1 1 1 411 Plug Band 1 1 1 1 412 Drain Valve 1 1 1 1 413 Stop Bracket 1 1 1 1 700 Printed Circuit Boar...

Страница 65: ...65...

Страница 66: ...Anti Frost Heater Assembly 1 1 1 1 712 120V Valve Heater Assembly 1 1 1 1 714 Thermal Fuse Harness 1 1 1 1 716 Thermistor 2 2 2 2 718 Frost Sensing Switch 1 1 1 1 720 Fuse Harness 1 1 1 1 721 Power S...

Страница 67: ...charges any removal installation or re installation charges any material and or permits required for installation re installation or repair or charges to return the defective heater and or component p...

Страница 68: ...a replacement part or at our option repair any part which fails to function within the parts warranty period To obtain a replacement you must forward the defective part to us If government regulations...

Страница 69: ...al or Commercial ____________________ ____________________ Model Number Serial Number ____________________ ____________________ Installation Company Installer s EverHot Certification Number Ex ABC Plu...

Страница 70: ...70 NOTES...

Страница 71: ...71 NOTES...

Страница 72: ...1670 Parts Fax 215 641 2180 Technical Support 800 334 3393 Fax 269 795 1089 Warranty 800 531 2111 Fax 269 795 1089 International Telephone 215 641 9400 Telefax 215 641 9750 Mississauga ON Sales 866 6...