38
Table 17.
Thermal Fuse / Overheat Switch.
Wire Color
Voltage
Resistance
Connector
No.
Pin
Nos.
Red-Red
11-13 VDC
Below 1 ohms
F6
H1
F6-
H12
Flame Rod:
Place one lead of your meter to the flame rod and the other to ground. With the unit running, you should
read between 5-150 VAC. Set your meter to µ amp scale and series your meter in line with the flame rod.
You should read 1 µ amp or greater for proper flame circuit. In the event of low flame circuit, remove the
flame rod and check for carbon or damage.
Heat Exchanger and Outgoing Water Temperature Thermistors:
Check all Thermistors by inserting meter leads into each end of the thermistor plug. Set your meter to the
20k scale and read resistance. Applying heat to the thermistor bulb should decrease the resistance.
Applying ice to the thermistor bulb should increase the resistance. See below for examples of typical
temperatures and resistance readings.
Example:
59ºF = 11.4-14k
Ω
140ºF
=
2.2-2.7k
Ω
86ºF = 6.4-7.8k
Ω
221ºF
=
0.6-0.8k
Ω
113º = 3.6-4.5k
Ω
Table 18.
Outgoing Water Thermistor.
Wire Color
Voltage
Resistance
Connector
No.
Pin
Nos.
White-White n/a
See example
above
F5 3-4
Table 19.
Heat Exchanger Temperature Thermistor.
Wire Color
Voltage
Resistance
Connector
No.
Pin
Nos.
Pink-White n/a
See example
above
F4 3-11
Table 20.
Intake Air Thermistor (Indoor Model Only).
Wire Color
Voltage
Resistance
Connector
No.
Pin
Nos.
Orange-White n/a
See example
above
F3 3-12
Table 21.
Surge Protector.
Wire Color
Voltage
Resistance
Connector
No.
Pin
Nos.
Black-White 108-132
VAC
n/a
D2
1-3
Blue-Brown 108-132
VAC
n/a
D1
1-3
With the power off, you can check the continuity through the surge protector. Place a meter lead on the
top pin #1 of the surge protector and pin #3 on the bottom of the surge protector. Check across the top
pin #3 and the bottom pin #1. If you read continuity across these two points, the surge protector is good.
If you do not get continuity, replace the surge protector.
Table 22.
Remote Controls.
Wire Color
Voltage
Resistance
Connector
No.
Pin
Nos.
Terminals B1
10-13 VDC
1.5-3.0k ohms
B
1-3
Содержание EverHot TG-150E-N
Страница 20: ...20 Figure 6 Recommended Piping for a Basic Installation...
Страница 21: ...21 Figure 7 Recommended Piping for a Circulation Systems...
Страница 25: ...25 Figure 9 Recommended Piping for Combination Water and Space Heating Applications...
Страница 31: ...31 Figure 11 Wiring Diagram for TG 150E N X TG 180E N X and TG 199E N X Models...
Страница 32: ...32 Figure 12 Wiring Diagram for TG 237E N X and TG 237E N X A Models...
Страница 51: ...51 SECTION IX PARTS LIST TG 150E TG 180E and TG 199E Models...
Страница 53: ...53...
Страница 55: ...55...
Страница 57: ...57...
Страница 59: ...59 TG 237E Models...
Страница 61: ...61...
Страница 63: ...63...
Страница 65: ...65...
Страница 70: ...70 NOTES...
Страница 71: ...71 NOTES...