3) Is the remote control normal ?
No combustion (despite remote control indication)
1) Is the water flow sensor normal ?
37
Check voltage between the two remote control cable
connectors.
a.
Check the voltage between terminals on the
remote control terminal mount D
1
.
Normal:
11 ~ 13 VDC
If normal, check for an open circuit or short before
replacing the remote control.
Faulty:
Replace PCB.
(Service Procedure IGI-2, page 49)
Check the water flow sensor.
a.
Check the voltage at PCB connector B4 , red and
black wires.
Normal:
11 ~ 13 VDC or 5.8 ~ 6.4K Ω
If normal, check (b) below.
Faulty:
Replace the PCB.
(Service Procedure IGI-2, page 49)
b.
Check the voltage at PCB connector B4, yellow and
black wires.
Normal:
4 ~ 7 VDC or 1M ~ 1.2M Ω.
If normal, proceed to check item 2 on next page.
Faulty:
Replace the water flow sensor.
(Service Procedure IGI-2, page 49)
VI - TROUBLESHOOTING
(cont.)
Содержание Everhot IGI-180C-5N
Страница 7: ...I GENERAL INFORMATION cont CUT AWAY ILLUSTRATION 7...
Страница 8: ...I GENERAL INFORMATION cont SCHEMATIC ILLUSTRATION 8...
Страница 21: ...V SEQUENCE OF OPERATION cont Operation Sequence Flow Chart 21...
Страница 22: ...V SEQUENCE OF OPERATION cont Operation Sequence Flow Chart 22...
Страница 23: ...V SEQUENCE OF OPERATION cont Sequence Timing Chart 23...
Страница 24: ...V SEQUENCE OF OPERATION cont Sequence Timing Chart 24...
Страница 30: ...Wiring Schematic 30...
Страница 55: ...55 X PARTS BREAKDOWN Disassembled View Cabinet...
Страница 56: ...X PARTS BREAKDOWN Disassembled View Internals 56...
Страница 57: ...X PARTS BREAKDOWN Disassembled View Internals 57...
Страница 58: ...X PARTS BREAKDOWN Disassembled View Electrical 58...
Страница 62: ...62 Notes...
Страница 63: ...63 Notes...